CALL NOWCALL NOWCALL NOWGATEWAY SELECTORCALL NOWGATEWAY SELECTORLEARN MORELEARN MORE PROCEED TO CHECK-OUT SUBSCRIBE TO OUR RSS FEED SEARCH GATEWAYS NOW SEND MESSAGE NEWSLETTER | SUBSCRIBESUBMIT CALL NOWCALL NOWCALL NOWGATEWAY SELECTORCALL NOWGATEWAY SELECTORLEARN MORELEARN MORE PROCEED TO CHECK-OUT SUBSCRIBE TO OUR RSS FEED SEARCH GATEWAYS NOW SEND MESSAGE NEWSLETTER | SUBSCRIBESUBMIT

DeviceNet Converters

DeviceNet is an open protocol but is mainly used with Rockwell Automation projects. If you don’t find what you are looking for then please visit the page with solutions for Rockwell.

Introduction

The FieldServer DeviceNet Master X30 Adapter driver can be used to emulate a single Master Scanner station on a DeviceNet network. The DeviceNet adapter is implemented as an ODVA profile 12 communications adapter. Standard DeviceNet baud rates of 125K, 250K and 500kbit/s are supported. DeviceNet Master Scanner can open an I/O connection of up to 512 Bytes in each direction to the DeviceNet Slaves.

The FieldServer DeviceNet Slave X30 Adapter driver can be used to emulate a single slave station on a DeviceNet network. The DeviceNet adapter is implemented as an ODVA profile 12 communications adapter and acts as a group 2 only server on the DeviceNet Network. Standard DeviceNet baud rates of 125K, 250K and 500kbit/s are supported. DeviceNet masters/scanners can open an I/O connection of up to 512 Bytes in each direction to the FieldServer

DeviceNet is a communication protocol used in the automation industry to interconnect control devices for data exchange. It uses Controller Area Network as the backbone technology and defines an application layer to cover a range of device profiles. Typical applications include information exchange, safety devices, and large I/O control networks.

DeviceNet was originally developed by American company Allen-Bradley (now owned by Rockwell Automation). It is layered on top of the CAN (Controller Area Network) protocol, developed by Bosch. In order to promote the use of DeviceNet worldwide, Rockwell Automation has adopted the “open” concept and decided to share the technology to third party vendors. Hence, it is now managed by the Open DeviceNet Vendors Association (ODVA), an independent organization located in North America. ODVA maintains specifications of DeviceNet and oversees advances to DeviceNet. In addition, ODVA ensures compliance to DeviceNet standards by providing conformance testing and vendor conformity.[3]

Convert

We have module solutions which allow integration directly into DeviceNet as well as the stand alone solutions shown bottom right.

Range of Conversion Solutions

Depending on project requirements select from units with varying resources. and multi port devices. OEM and embedded solutions too.

QuickServer 10102x RS4851x Ethernet
QuickServer 10111x RS4851x Ethernet1x Lonworks
QuickServer 12101x RS485 1xRS2321x Ethernet
QuickServer 12111x RS485 1xRS2321x Ethernet1x Lonworks
QuickServer Fieldbus1x RS4851x EthernetM-bus or KNX
FS20 Series1x RS232/4851x Ethernet1x Lonworks
FS25 Series2x RS232/4851x Ethernet
FS30 Series2x RS232 and 2x RS4852x Ethernet1x LonworksFieldBus Support:eg Profibus, DeviceNet etcHot Standby Support
FS40 Series8x RS232 and 2x RS4852x Ethernet1x LonworksFieldBus Support: eg DH+, MB+, Profibus, DeviceNet etcHot Standby Support
SlotServer1x RS232/4851x Ethernet1x LonworksFor Rockwell ControlLogix 5600

Lonworks and Fieldbus are options not proviced on base models.


Block Diagram 

FS30 series shown for purposes of illustration. Capability depends on hardware, firmware and configuration.


Data Sheets and Manuals 

 – Data Sheet – FieldServer Driver – Fieldbus – FS–8700–114 – X30 DeviceNet Master Adapter Driver

 – Manual – FieldServer Driver – Fieldbus – FS–8700–114 – X30 DeviceNet Master Adapter Driver
 – FieldServer Driver – Fieldbus – FS–8700–22 – X30 DeviceNet Slave Adapter Driver
 – Manual – FieldServer Driver – Fieldbus – FS–8700–22 – X30 DeviceNet Slave Adapter Driver

More Data Sheets

Need Help

DeviceNet Wikipedia: en.wikipedia.org/wiki/DeviceNet

Need more info ? Call or email us.

Metasys® as used in this document is a trademark of Johnson Controls, Inc.

Gateway Selector

Select your combination of protocols.
Protocol 1
Protocol 2

Contact Us

Contact us via phone (+1 866-383-1657) or leave a detailed message below for sales, support, or any other needs

*Required Field
I'd like to receive the newsletter. *Check email for confirmation.
*Required Field
Preferred Time To Be Contacted (PST)
8:00am - 12:00pm 12:00pm - 5:00pm