CALL NOWCALL NOWCALL NOWGATEWAY SELECTORCALL NOWGATEWAY SELECTORLEARN MORELEARN MORE PROCEED TO CHECK-OUT SUBSCRIBE TO OUR RSS FEED SEARCH GATEWAYS NOW SEND MESSAGE NEWSLETTER | SUBSCRIBESUBMIT CALL NOWCALL NOWCALL NOWGATEWAY SELECTORCALL NOWGATEWAY SELECTORLEARN MORELEARN MORE PROCEED TO CHECK-OUT SUBSCRIBE TO OUR RSS FEED SEARCH GATEWAYS NOW SEND MESSAGE NEWSLETTER | SUBSCRIBESUBMIT

OPC Data Conversion


The FieldServer OPC Server installs on a windows computer and functions in the same way as all other OPC Servers in its ability to serve data to clients on the same or networked computers. However, its data source is a FieldServer connected via an Ethernet network. The FieldServer can be loaded with any FieldServer drivers (over 100 protocols supported) and can access data from Fire Panels, HVAC equipment, PLCs and many other devices.

The S4 Group: N2 OPC Server is a product aimed at making JCI Metasys N2 by JCI data available as OPC data. When connected to a N2 network , it scans all the devices and automates the mapping of all data points to OPC data.

Block diagrams for both solutions are show below.

Convert

We have module solutions which allow integration directly into OPC products as well as the stand alone solutions shown bottom right.

Range of Conversion Solutions

Depending on project requirements select from units with varying resources. and multi port devices. OEM and embedded solutions too.

QuickServer 10102x RS4851x Ethernet
QuickServer 10111x RS4851x Ethernet1x Lonworks
QuickServer 12101x RS485 1xRS2321x Ethernet
QuickServer 12111x RS485 1xRS2321x Ethernet1x Lonworks
QuickServer Fieldbus1x RS4851x EthernetM-bus or KNX
FS20 Series1x RS232/4851x Ethernet1x Lonworks
FS25 Series2x RS232/4851x Ethernet
FS30 Series2x RS232 and 2x RS4852x Ethernet1x LonworksFieldBus Support:eg Profibus, DeviceNet etcHot Standby Support
FS40 Series8x RS232 and 2x RS4852x Ethernet1x LonworksFieldBus Support: eg DH+, MB+, Profibus, DeviceNet etcHot Standby Support
SlotServer1x RS232/4851x Ethernet1x LonworksFor Rockwell ControlLogix 5600

Lonworks and Fieldbus are options not proviced on base models.

Block Diagram 

FS30 series shown for purposes of illustration. Capability depends on hardware, firmware and configuration.

The S4 Open: OPC-N2 Router offers flexibility and cost savings when integrating legacy Metasys® N2 by JCI networks to Open Systems. The OPC-N2 Router avoids costly replacement or re-engineering of existing devices on legacy N2 buses. Typical Applications would be to bring data from the Metasys® N2 by JCI network into OPC-based enterprise applications, energy management applications, or adding best-of-breed OPC-based head end systems and HMIs from Johnson Controls or 3rd parties to legacy Metasys® by JCI installations.

 – S4 Open: OPC-N2 Router Product Capabilities

Data Sheets and Manuals

 – Data Sheet – FieldServer Driver – Serial – FS-8707-06 – FST OPC Server for FieldServers

 – Manual – FieldServer Driver – Serial – FS-8707-06 – FST OPC Server for FieldServers

More Data Sheets

Need Help 

OPC Web Site: www.opcfoundation.org

Need more info ? Call or email us.

Metasys® as used in this document is a trademark of Johnson Controls, Inc.

Gateway Selector

Select your combination of protocols.
Protocol 1
Protocol 2

Contact Us

Contact us via phone (+1 866-383-1657) or leave a detailed message below for sales, support, or any other needs

*Required Field
I'd like to receive the newsletter. *Check email for confirmation.
*Required Field
Preferred Time To Be Contacted (PST)
8:00am - 12:00pm 12:00pm - 5:00pm