CALL NOWCALL NOWCALL NOWGATEWAY SELECTORCALL NOWGATEWAY SELECTORLEARN MORELEARN MORE PROCEED TO CHECK-OUT SUBSCRIBE TO OUR RSS FEED SEARCH GATEWAYS NOW SEND MESSAGE NEWSLETTER | SUBSCRIBESUBMIT CALL NOWCALL NOWCALL NOWGATEWAY SELECTORCALL NOWGATEWAY SELECTORLEARN MORELEARN MORE PROCEED TO CHECK-OUT SUBSCRIBE TO OUR RSS FEED SEARCH GATEWAYS NOW SEND MESSAGE NEWSLETTER | SUBSCRIBESUBMIT

SNMP Data Conversion

There are two solution platforms for SNMP

FieldServer – FieldServer can read data using over 110 protocols from device like Fire Panels, PLC’s Gensets, HVAC etc. Almost all of this data can be served as SNMP data – you poll for it and/or it can be served as traps. In addition, FieldServers can monitor SNMP enabled devices such as UPS’s and serve that data using other protocols so the data can be integrated into Building and Industrial Systems.

FieldServer have 2x SNMP Drivers. They are both v1 drivers and while similar they have important differences in the way TRAPS carry their payload and some other important differences.

SNMP — FS-8704-09 (aka FieldServer legacy SNMP Driver)

SNMP — FS-8704-26 (aka FieldServer Standard SNMP Driver)


S4 Open – The S4 Open platform connects SNMP enabled devices to an OPC server so HMI’s and control systems can monitor and command the SNMP enabled devices. A high degree of automation is provided based on automatic discovery of SNMP devices and walks through their MIB trees.

Convert

We have module solutions which allow integration directly into SNMP as well as the stand alone solutions shown bottom right.

Range of Conversion Solutions

Depending on project requirements select from units with varying resources and multi port devices. OEM and embedded solutions too.

FS20 Series1x RS232/4851x Ethernet1x Lonworks
FS25 Series2x RS232/4851x Ethernet
FS30 Series2x RS232 and 2x RS4852x Ethernet1x LonworksFieldBus Support:eg Profibus, DeviceNet etc
Hot Standby Support
FS40 Series10x RS232 and 2x RS4852x Ethernet1x LonworksFieldBus Support: eg DH+, MB+, Profibus, DeviceNet etc
Hot Standby Support
SlotServer1x RS232/4851x Ethernet1x LonworksFor Rockwell ControlLogix 5600

Lonworks and Fieldbus are options not proviced on base models.

Block Diagram

The block diagram below illustrates the FieldServer Platform solution

S4 Solutions for SNMP to OPC

The block diagram below illustrates the S4 Open solution platform

  • Translates OPC Read Requests to SNMP GET Commands
  • Translates OPC Write Requests to SNMP SET Commands
  • Maps SNMP Traps to OPC Alarms and Events
  • Supports SNMP Autodiscovery
  • Automatically selects the correct Device Profile and assigns it to SNMP devices
  • Integrates SNMP Manageable devices into Automation Systems
  • Supports NON-SNMP devices via ICMP

Data Sheets and Manuals

 – Data Sheet – FieldServer Driver – Ethernet – FS-8704-09 – SNMP

 – Manual – FieldServer Driver – Ethernet – FS-8704-09 – SNMP

 – S4 Group – The Obermeier Software SNMP OPC Server v3.0 Product Sheet

More Data Sheets

Need Help

SNMP Web Site: www.net-snmp.org

Need more info ? Call or email us.

Metasys® as used in this document is a trademark of Johnson Controls, Inc.

Gateway Selector

Select your combination of protocols.
Protocol 1
Protocol 2

Contact Us

Contact us via phone (+1 866-383-1657) or leave a detailed message below for sales, support, or any other needs

*Required Field
I'd like to receive the newsletter. *Check email for confirmation.
*Required Field
Preferred Time To Be Contacted (PST)
8:00am - 12:00pm 12:00pm - 5:00pm