Intesis Modbus

Intro to Modbus

Modbus is a serial communications protocol originally published by Modicon (now Schneider Electric) for use with its programmable logic controllers (PLCs). Modbus has become a de facto standard communication protocol and is now a commonly available means of connecting industrial electronic devices.

Modbus enables communication among many devices connected to the same network and is often used to connect a supervisory computer with a remote terminal unit (RTU) in supervisory control and data acquisition (SCADA) systems.


For further information, please visit www.modbus.org

IntesisBox - Modbus gateways and AC interfaces

Chipkin's Intesis Modbus gateways have been specially designed to allow supervision and bidirectional control of all the parameters and functionality of systems and equipment with KNX, MBUS, BACnet/IP, BACnet MSTP, LonWorks, and DALI installations and Atersa or Fidelio systems from Modbus installations.

  • Easy installation. Direct connection to RS-485 or Ethernet and the AC indoor unit.
  • Great integration flexibility.
  • Advanced integration with any SCADA such as Wonderware, Intellution, ABB, Schneider... as well as energy and gas meters, PLC’s, coolers, fan-coil controllers, fire panels, security panels, etc.

IntesisBox - Modbus AC gateways

Specially designed, in collaboration with several manufacturers like Mitsubishi Electric, Daikin, Samsung, Fujitsu to allow supervision and bidirectional control of all the parameters and functionality of Air conditioners from Modbus installations.

  • Easy installation. Direct connection to RS-485 or Ethernet and the AC indoor unit
  • Great integration flexibility, with supervision and control of BACnet Objects and properties allowing an easy and fast integration with the basic parameters and a complete supervision and control for all the AC unit functionality
  • Advanced integration with air conditioner: a complete bidirectional communication and simultaneous control from Modbus and the infrared Air Conditioner remote controller.

Gateway Selector

Select your combination of protocols.
Protocol 1
Protocol 2

Related Products

Contact Us

Contact us via phone (+1 866-383-1657) or leave a detailed message below for sales, support, or any other needs

*Required Field
I'd like to receive the newsletter. *Check email for confirmation.
*Required Field
Preferred Time To Be Contacted (PST)
8:00am - 12:00pm 12:00pm - 5:00pm