Metasys N2 to Bacnet Ethernet

A FieldServer protocol gateway that provides data exchange between Metasys N2 and Bacnet Ethernet QuickServer is a high performance, fully configurable, cost effective Building and Industrial Automation gateway for integrators to easily interface ...
SKU:
FS-QS-1XX0-0076
Max Points
Max Points: 250, 500
Metasys N2 to Bacnet Ethernet

Metasys N2 to Bacnet Ethernet


Quickserver Gateway (Serial-Ethernet)

QuickServer is a high performance, fully configurable, cost effective Building and Industrial Automation gateway for integrators to easily interface devices to networks in commercial buildings and industrial plants.

System integrators world-wide have benefitted from the value of the powerful line of interoperability gateways offered by FieldServer. Now, QuickServer adds to that value by running the same robust FieldServer protocol conversion software on a highly cost effective platform backed by the experience, engineering expertise and proven technical support that integrators have come to expect from FieldServer.

QuickServer is available in two series. The FS-QS-10XX Series is preloaded with two BAS drivers (serial, Ethernet and/or LonWorks) from a choice of Modbus RTU, Modbus TCP, BACnet/IP®, BACnet MS/TP, LonWorks®, JCI Metasys® N2 and SNMP. Each QuickServer can handle up to 250 points.

The FS-QS-12XX Series QuickServer is available to use any Serial, Ethernet or LonWorks driver in the extensive FieldServer driver library. The FS-QS-12XX Series can handle up to 500 points and is available with a choice of RS-485, RS-232 or RS- 422 serial ports, KNX or M-Bus, in addition to Ethernet and LonWorks (optional).

Each QuickServer includes browser-based tools to make it easy to set-up QuickServer and perform diagnostics including determination of status, network settings, node information, map descriptors and more. The USB flash drive also includes the Discovery utility to determine what FieldServers are on a network.

Metasys N2

The Metasys® N21 by Johnson Controls network supports communications with a diverse range of devices. Many N2 compatible devices use their own version of the protocol and care must be taken to ensure that the device of interest is covered by the FieldServer implementation.

At present the FieldServer Metasys® N2 driver will support communications with the following devices or classes of devices when acting as a Client:

  • N2Open-compliant devices. N2Open is a published N2-compatible protocol enabling 3rd party device vendors to integrate with N2.
  • VMA 1400 series (with restrictions)
  • DX9100 and XT9100

When acting as a Server the FieldServer Metasys® N2 driver can emulate an N2Open device only.

BACnet Ethernet

The BACnet®1suite of drivers is designed to workwith the FieldServer products. One or more driversusing different Data Link Layer options could beconfigured to act as a gateway between BACnetsystems and RTU, SCADA's and PLC’s using a widevariety of protocols.

This is relevant to the following FieldServerDrivers:

  • FS-8700-16 BACnet/PTP
  • FS-8700-73 BACnet/MSTP
  • FS-8700-07 BACnet/ARCnet
  • FS-8704-06 BACnet/IP
  • FS-8704-02 BACnet/Ethernet
BACnet Vendor Name: Sierra Monitor CorporationBACnet Vendor ID: 37 

Manuals

FS-8704-02 BACnet Ethernet_Manual
FS-8700-19 Metasys N2 by Johnson Controls Protocol Manual
QuickServer Start-up Guide

Datasheets

BACnet Combined Protocol Data Sheet
FS-8700-19 Metasys N2 by Johnson Controls Protocol Data Sheet
QuickServer Data Sheet

Resources

ComBus Quick Tester Manual
Metasys N2 by JCI - ComBus Quick Tester Manual
Johnson Controls Metasys N2 Communications Interface Technical Manual
Metasys N2 by JCI - N2 Communication Bus Tech Bulletin
Metasys N2 by JCI - UNT110 UNT111 controller
Metasys N2 by JCI - checksum analysis
Metasys N2 by JCI - HVAC_PRO_help files
Metasys N2 by JCI - Device Points
Metasys N2 by JCI - DX9100 ConfigGuide
Metasys N2 by JCI - DX9100 Wiring
Metasys N2 by JCI - NAE Configuration
Metasys N2 by JCI - Metasys Unitary Controller (UNT)
Metasys N2 by JCI - vma1420

Block Diagrams

LP Metasys N2 Open - All Solutions