CALL NOW CALL NOW CALL NOW GATEWAY SELECTOR CALL NOW GATEWAY SELECTOR LEARN MORE LEARN MORE PROCEED TO CHECK-OUT SUBSCRIBE TO OUR RSS FEED SEARCH GATEWAYS NOW SEND MESSAGE SUBMIT

1-Wire

Intro to 1-Wire

1-Wire is a device communications bus system that provides low-speed data, signaling, and power over a single conductor. It’s similar in concept to I²C, but with lower data rates and longer range. It is typically used to communicate with small inexpensive devices such as digital thermometers and weather instruments.

One distinctive feature of the bus is the possibility of using only two wires: data and ground. To accomplish this, 1-Wire devices include an 800 pF capacitor to store charge, and to power the device during periods when the data line is active.

Chipkin has developed multiple devices to facilitate 1-Wire communication. Our solutions read, log, convert, or push to could 1-Wire messages from a DS18b20 temperature sensor.

Our 1-Wire devices require minimal configuration and can be considered a ‘plug and play’ component of any network system. It’s ready to operate ‘out of the box’ and can be installed without an engineer’s approval.

Important: The serial driver uses an RS232 serial port to connect the 1-Wire network and a 1-wire to RS232 converter must be installed on the Chipkin Gateway.


CAS Gateway: 1-Wire to Modbus RTU/TCP, BACnet IP and HTTP
  

Product Description

Chipkin™ 1-Wire™ Modbus® RTU/TCP, BACnet® and HTTP gateway is a protocol converter for 1-Wire DS18b20 temperature sensors. The gateway operates by reading the temperature data from the 1 or more DS18b20 1-wire sensors into an internal database. The values read from these sensors can then be read from Modbus® RTU/TCP, BACnet® and HTTP.


The gateway requires minimal configuration and can be considered a ‘plug and play’ component of any network system. It’s ready to operate ‘out of the box’ and can be installed without an engineer’s approval.

  

Product Description

Chipkin’s CAS-Bridge 1-Wire to Modbus TCP/RTU and IoT, monitors a series of 1-Wire temperature sensors and makes the data available to Modbus devices, as well as logging long-term trending data into the cloud. The CAS-Bridge operates by monitoring the 1-Wire temperature sensors and storing the values in an internal database. Then serving the temperature data as Modbus TCP/RTU values. When a value changes or a timeout occurs, the values are sent to an online dashboard for long-term trending and logging.


The CAS Bridge can be connected to your network with an ethernet connection or by connecting to a WiFi access point.

CAS Data Client - 1-Wire
  

Product Description

Chipkin™ 1-Wire™ Data Client connects to 1-Wire DS18b20 temperature sensors. The Data Client operates by reading the temperature data from 1 or more sensors. The data and transactions are logged into an internal database which are available and can be transferred to other computers and monitored by remote systems. Of course, this data is also available using an Internet Browser such as Google Chrome. Connection, device, and data parameters are configurable.


The Data Client requires minimal configuration and can be considered a ‘plug and play’ component of any network system. It’s ready to operate ‘out of the box’ and can be installed without an engineer’s approval.

  

Product Description

Chipkin™ 1-Wire™ Windows gateway is a protocol converter for 1-Wire DS18b20 temperature sensors. The gateway operates by reading the temperature data from 1 or more sensors and storing them inside a database. The values can then be read from Modbus® RTU/TCP, BACnet® and HTTP.


The gateway requires minimal configuration and can be considered a ‘plug and play’ component of any network system. It’s ready to operate ‘out of the box’ and can be installed without an engineer’s approval.

Thanks for choosing Chipkin’s protocol gateways, data clients, and integration services to meet your building and industrial automation requirements!

Chipkin™ is a building and industrial automation protocol expert. We develop, configure, install and support gateways (protocol converters), data loggers and remote monitor and controlling applications. Founded in October 2000, Chipkin provides expert solutions for converting BACnet®, Modbus®, and LonWorks®—to name just a few—and enabling interfaces for HVAC, fire, siren, intercom, lighting, transportation and fuel systems. The high-quality products we offer (including those from other vendors) interface with Simplex™, Notifier™, McQuay™, GE™ and many others—so you can rest assured that we will select the most appropriate solution for your application.

With Chipkin you are buying a solution. Our configuration expertise in this field combined with free BACnet and other tools ensure your success; and our customer support via phone, e-mail, and remote desktop tools means that we’re there when you need us. Chipkin is a small responsive company, and we live or die by the quality of our service—and with offices in two-time zones—we can provide support when you need it. Give us a call now!

Customer Support

The 1-Wire products were developed by Chipkin, and we are proud to provide support for our products.

For technical support, sales, and customer service, please contact us at 1 (866) 383-1657

Gateway Selector

Select your combination of protocols.
Protocol 1
Protocol 2

Related Products

Contact Us

Contact us via phone (+1 866-383-1657) or leave a detailed message below for sales, support, or any other needs

*Required Field
I'd like to receive the newsletter. *Check email for confirmation.
*Required Field
Preferred Time To Be Contacted (PST)
8:00am - 12:00pm 12:00pm - 5:00pm