SNMP Std

Intro to SNMP Simple Network Management Protocol (SNMP) is an Internet Standard protocol for collecting and organizing information about managed devices on IP networks and for modifying that information to change device behavior. Devices that typically support SNMP Std include cable modems, routers, switches, servers, workstations, printers, etc. SNMP Std is widel
Read More

DNP 3.0 Ethernet and DNP 3.0 Serial

Intro to DNP 3.0 DNP3 (Distributed Network Protocol) is a set of communications protocols used between components in process automation systems. Its main use is in utilities such as electric and water companies. DNP3 was developed for communications between various types of data acquisition and control equipment and plays a crucial role in SCADA systems, where
Read More

1-Wire

Intro to 1-Wire 1-Wire is a device communications bus system that provides low-speed data, signalling, and power over a single conductor. It’s similar in concept to I²C, but with lower data rates and longer range. It is typically used to communicate with small inexpensive devices such as digital thermometers and weather instruments. One distinctive fe
Read More

BACnet BTL Pre-Testing

BTL Testing: The problem BACnet is not a simple protocol and requires extensive testing to ensure compatibility between devices. The BACnet Testing Laboratory (BTL) provides testing and certification for BACnet devices to ensure that there are no compatibility issues between different manufacturers’ BACnet devices. Sending a new BACnet device to the B
Read More

Password Managers - Part 1

Intro to Password Managers: Virtually everybody today has a username and password. We are required to provide them to log on to popular online services like social media, online stores, and streaming services. By default, browsers will ask you if you want to save passwords to save you the trouble of typing them again. If yo
Read More

Custom Hardware and Software Solutions

How Can We Help! Often legacy equipment utilizes protocols to communicate which are not supported by modern devices or networks. We take these legacy protocols and convert them to BACnet or Modbus or any other protocol to save you the hassle and expense of replacing the legacy equipment. Chipkin is committed to finding solutions to any type of communicatio
Read More

CAS BACnet Explorer Giveaway - November 2018

Enter for a Chance to Win: a Rafflecopter giveaway Previous Winners: We would like to congratulate Tristan H. for being the winner of our giveaway in March 2018. As a bonus, we also provided 10 extra BACnet Explorer keys!
Read More

Fully Automated 50-ton Bulldozer

Intro to Automated Machinery: With the advent of Autonomous driving technology, even large construction equipment like bulldozers, Excavators, Drilling machines are now driving fully autonomously! It’s Incredible isn’t it? Let’s have a look at them. Fig:
Read More

Gateway Selector

Select your combination of protocols.
Protocol 1
Protocol 2

Contact Us

Contact us via phone (+1 866-383-1657) or leave a detailed message below for sales, support, or any other needs

*Required Field
I'd like to receive the newsletter. *Check email for confirmation.
*Required Field
Preferred Time To Be Contacted (PST)
8:00am - 12:00pm 12:00pm - 5:00pm