Intesis Modbus
Intro to Modbus
Modbus is a serial communications protocol originally published by Modicon (now Schneider Electric) for use with its programmable logic controllers (PLCs). Modbus has become a de facto standard communication protocol and is now a commonly available means of connecting industrial electronic devices.
Modbus enables communication among many devices connected to the same network and is often used to connect a supervisory computer with a remote terminal unit (RTU) in supervisory control and data acquisition (SCADA) systems.
IntesisBox - Modbus gateways and AC interfaces
Chipkin's Intesis Modbus gateways have been specially designed to allow supervision and bidirectional control of all the parameters and functionality of systems and equipment with KNX, MBUS, BACnet/IP, BACnet MSTP, LonWorks, and DALI installations and Atersa or Fidelio systems from Modbus installations.
- Easy installation. Direct connection to RS-485 or Ethernet and the AC indoor unit.
- Great integration flexibility.
- Advanced integration with any SCADA such as Wonderware, Intellution, ABB, Schneider... as well as energy and gas meters, PLC’s, coolers, fan-coil controllers, fire panels, security panels, etc.
IntesisBox - Modbus AC gateways
Specially designed, in collaboration with several manufacturers like Mitsubishi Electric, Daikin, Samsung, Fujitsu to allow supervision and bidirectional control of all the parameters and functionality of Air conditioners from Modbus installations.
- Easy installation. Direct connection to RS-485 or Ethernet and the AC indoor unit
- Great integration flexibility, with supervision and control of BACnet Objects and properties allowing an easy and fast integration with the basic parameters and a complete supervision and control for all the AC unit functionality
- Advanced integration with air conditioner: a complete bidirectional communication and simultaneous control from Modbus and the infrared Air Conditioner remote controller.
List of Intesis Modbus Gateways
- Daikin AC Domestic units to Modbus Interface
- Daikin VRV and Sky systems to Modbus Interface
- Fujitsu RAC and VRF systems to Modbus Interface
- Hitachi VRF systems to Modbus Interface
- Hisense VRF systems to Modbus Interface
- Modbus to BACnet Gateway
- Modbus RTU to BACnet Gateway
- Modbus TCP to BACnet Gateway
- Modbus to KNX Gateway
- Algorex to Modbus Gateway
- Algorinet to Modbus Gateway
- ATERSA to Modbus Gateway
- BACnet to Modbus Gateway
- Cerberus to Modbus Gateway
- DALI to Modbus Gateway
- FC330A to Modbus Gateway
- Fidelio to Modbus Gateway
- Galaxy to Modbus Gateway
- Kilsen to Modbus Gateway
- KNX to Modbus Gateway
- Sunways to BACnet Gateway
- LonWorks to Modbus Gateway
- M-Bus to Modbus Gateway
- Notifier to Modbus Gateway
- Modbus RTU to Modbus TCP Gateway
- LG VRF systems to Modbus Gateway
- LG VRF systems to Modbus Interface
- Midea VRF systems and commercial lines to Modbus Gateway
- Mitsubishi Electric AC units to Modbus Interface
- Mitsubishi Electric AC Multi systems to Modbus Gateway
- Mitsubishi Heavy Industries SuperLink systems to Modbus Gateway
- Mitsubishi Heavy Industries FD and KX6 systems to Modbus Interface
- Panasonic Etherea AC units to Modbus Interface
- Panasonic VRF systems (CZ-CFUNC2) to Modbus Gateway
- Panasonic Air-to-Water to Modbus Interface
- Panasonic Aquarea Air-to-Water to Modbus Interface
- Panasonic ECOi and PACi systems to Modbus Interface
- Samsung NASA VRV systems to Modbus Gateway
- Toshiba VRF and Digital systems to Modbus Interface