CALL NOW CALL NOW CALL NOW GATEWAY SELECTOR CALL NOW GATEWAY SELECTOR LEARN MORE LEARN MORE PROCEED TO CHECK-OUT SUBSCRIBE TO OUR RSS FEED SEARCH GATEWAYS NOW SEND MESSAGE SUBMIT

Modbus TCP to BACnet Gateway

The IntesisBox Gateway has been specially designed to allow bidirectional control and monitoring of all parameters and functionalities of Modbus TCP slave devices from a BMS, SCADA or any other device working as a BACnet client.
SKU:
IBOX-BAC-MBTCP-100 (100 points and 5 devices), IBOX-BAC-MBTCP-A (500 points and 5 devices), IBOX-BAC-MBTCP-B (3000 points and 5 devices)
modbus-tcp-bacnet-server-ibox-bac-mbtcp-s1485777986 -

The IntesisBox Gateway has been specially designed to allow bidirectional control and monitoring of all parameters and functionalities of Modbus TCP slave devices from a BMS, SCADA or any other device working as a BACnet client.

The Modbus TCP to BACnet Gateway has been specially designed to allow bidirectional control and monitoring of all parameters and functionalities of Modbus TCP slave devices from a BMS, SCADA or any other device working as a BACnet client.

The aim of this integration is to make accessible Modbus TCP system signals and resources from a BACnet/IP based control system or device as if it was a part of the own BACnet system and vice-versa. For this, the gateway acts as a BACnet/IP Server device in its BACnet interface, allowing other BACnet/IP devices to perform subscription (COV) requests, and also read and write its internal points.

From the Modbus TCP system point of view, after the start-up process, IntesisBox reads continuously the points configured to be read in the Modbus TCP slave devices, and updates in its memory all the values received from the Modbus TCP system.

From the BACnet system point of view, after the start-up process, the gateway listen for any subscription (COV) request, serves any polling request, or performs any writing request of its internal points received from BACnet system. The values received from BACnet are immediately written in the associated register of the corresponding Modbus TCP slave device.

Specifications


Block Diagrams

/2018/feb/06-01-54-48_IBOX-BAC-MBTCP-xxx.png

Gateway Selector

Select your combination of protocols.
Protocol 1
Protocol 2

Related Products

Contact Us

Contact us via phone (+1 866-383-1657) or leave a detailed message below for sales, support, or any other needs

*Required Field
I'd like to receive the newsletter. *Check email for confirmation.
*Required Field
Preferred Time To Be Contacted (PST)
8:00am - 12:00pm 12:00pm - 5:00pm