Notifier Onyx 640 to SNMP Multiport Gateway

A FieldServer protocol gateway that provides data exchange between Notifier Onyx 640 and SNMP.
The Multiport Gateway provides a wealth of features to enable data transfer between different devices and networks.
The NFS-640 Serial driver allows the FieldServer to record data from Notifier Onyx Series NFS-640, NFS2-640 and NFS-320 Fire Panels over RS-232.
The SNMP-STD driver allows the FieldServer to transfer data to and from devices over Ethernet using the SNMP Version V1 or V2c protocol.
SKU:
FS-B3510-1086
Sqrd resized WT BG png - Sqrd resized WT BG png

Multiport Gateway (Serial-Ethernet-LonWorks)

This protocol translator/gateway provides a wealth of features to enable data transfer between different devices and networks utilizing serial, Ethernet or LonWorks ports. The extensive library of FieldServer drivers provides easy interoperability with devices and networks used in building automation, HVAC, fire and process control industries.

The FS-B3510 is one of the FS-X30 Series FieldServers designed to meet the needs of system integrators in designing a complete interoperable system. The FS-B30 Series brings together the powerful FieldServer driver library with state-of-the-art gateway design. This FieldServer includes four serial connections (two RS-232, two RS-485), two Ethernet ports, and a LonWorks port. The multiport design allows for serial-to-serial interfaces or interface from mulitple serial products to an Ethernet or LonWorks network. The two Ethernet ports enable the integrator to connect a PC to download configuration changes without disturbing the system connections and without the additional cost of an external hub.

SNMP (std)

The SNMP-STD driver allows the FieldServer to transfer data to and from devices over Ethernet using the SNMP Version V1 or V2c protocol. The FieldServer can emulate a Server (SNMP Agent) or Client (NMS Network Management Station).

The FieldServer provides a generic MIB (Management Information Base) file that sets out the OID (Object Identifiers) structure. The FieldServer Enterprise ID is 6347. A selection of standard MIB-2 OID’s are supported to allow interaction with popular Network Management packages.

When configured as an SNMP Agent (Server) the SNMP-STD driver allows SNMP Get, GetNext (walk) and Set commands to access Data Arrays using the Integer type. The SNMP v1 protocol does not make provision for Floats.

The SNMP-STD driver can send SNMP traps. The structure for SNMP Traps is provided in the FieldServer’s generic MIB file.

The FieldServer also supports custom MIBs and the automatic generation of the MIB file. It supports setting a custom enterprise ID, object names and custom traps or informs. In custom configurations the FieldServer supports various data types as specified in Section 6.1 of the Manual.

When configured as a Client, the FieldServer can read objects from the Server using Get, GetNext (walk) or GetBulk commands. The GetBulk command is very useful to transfer large amounts of data. The FieldServer can update objects in Agent using the Set command.

The FieldServer can accept any trap or inform as long as all the objects in the message are encoded with a full OID.

The Client side of the driver is considered as a custom configuration.

Notifier ONYX NFS-640 (NFS-640, NFS2-640 and NFS-320)

The NFS-640 Serial driver allows the FieldServer to record data from Notifier Onyx Series NFS-640, NFS2-640 and NFS-320 Fire Panels over RS-232. The FieldServer primarily acts as a Passive Client receiving unsolicited messages and updating the status of a Notifier Fire Alarm Panel.

The main purpose of this driver is to record the status of Fire Alarm System detectors and modules in a bit oriented Data Array. It is limited by the information that the Notifier Panel broadcasts in the form of text messages through its RS-232 communication port. The accuracy and timeliness of the data is therefore limited by the frequency of update messages that the Notifier Fire Panel issues.

The types of Notifier messages supported by this driver are summarized in Appendix C.1 of the manual. A detailed table showing each type of panel message the FieldServer recognizes and the effect that it has on the status of points in the data array is presented in Appendix C.2 of the manual. The device status to the data array mapping is also provided in Appendix C.2 of the manual.

It is possible to connect through the CRT Port., however the use of this port restricts the use of Notifier Networking, thus a fire panel connected to a Noti-Fire-Net will not be supported. If the CRT port is used, the FieldServer can actively request the status of all points, devices and zones on a periodic basis. This status request is configurable from 5minutes with no upper bounds. Note that communication through this port does not equate to Port Supervision. Refer to Appendix A.1 of the Manual.

The panel must output messages in English. For Notifier 640 Onyx firmware with Spanish firmware (as sold in Mexico and other Central and South American markets) please refer to the fact sheet ‘FST_DFS_Notifier_NFS-640 (Onyx)(Spanish)’

I'd like to inquire about the Notifier Onyx 640 to SNMP Multiport Gateway FS-B3510-1086. Please provide me with a quote for this product.

Specifications

Multiport Gateway (Serial-Ethernet-LonWorks)

Field Connections
  • Ethernet Ports – 2: 100 BaseT RJ45 connector (auto MDIX and sensing) with ESD protection
  • Serial Ports – 5: 2 x RJ45 RS-232 galvanically isolated with ESD protection. 2 x RS-485 galvanically isolated with ESD protection. 1 x RJ45 RS-232 system port.
  • LonWorks – 1: FTT-10 twisted pair. 1000 Network variable capability. LonWorks service pin
  • Auxiliary ports – 2: 2 x USB ports. Expansion: Fieldbus connectors available for selected protocol
Environment
  • Operating Temperature: 0-60°C  (32-140°F)
  • Relative Humidity: 10-90% non-condensing
Power Requirements

24V AC (+/-10%) or 12-30V DC @ 12W

Physical Dimensions
  • Dimensions (WxDxH): 6.3x5.4x2.0 in.(16.0x13.7x5.0cm)
  • Weight: 2.5 lbs (1.5 Kg)
  • Input voltage: 24 V DC nominal: 10-30V DC
Other

Configuration/Diagnostic utilities

  • Capacity: Base system has 1000 point capability (upgradeable to 10,000 points)
  • Mounting Options: Desktop, Wall, Panel Optional: DIN rail
LED Indicators

Power, Run, System Error, Configuration Error, and Node Offline

Ethernet connection– Link OK, Tx/Rx communication activity

RS-232/RS-485 – Tx/Rx communication activity

LonWorks - Activity

Communication, Option, Drivers

Memory upgrade for additional data points

Custom Configuration Service

Drivers available for a wide range of Ethernet and social protocols

Approvals
  • CE Marked
  • CSA Certified: UL916 Standard and CSA @ 22.2
  • DNP 3.0 Tested
  • RoHS Compliant
  • GOST-R Certified
  • FCC: Part 15
  • LonMark Certified
  • Modbus Tested
  • BTL Certified

Block Diagrams

Notifier Gateway Connections Block Diagramimports/blockDiagrams/LP SNMP.jpg

Contact Us

Contact us via phone (+1 866-383-1657) or leave a detailed message below for sales, support, or any other needs