CALL NOWCALL NOWCALL NOWGATEWAY SELECTORCALL NOWGATEWAY SELECTORLEARN MORELEARN MORE PROCEED TO CHECK-OUT SUBSCRIBE TO OUR RSS FEED SEARCH GATEWAYS NOW SEND MESSAGE NEWSLETTER | SUBSCRIBESUBMIT CALL NOWCALL NOWCALL NOWGATEWAY SELECTORCALL NOWGATEWAY SELECTORLEARN MORELEARN MORE PROCEED TO CHECK-OUT SUBSCRIBE TO OUR RSS FEED SEARCH GATEWAYS NOW SEND MESSAGE NEWSLETTER | SUBSCRIBESUBMIT

Metasys N2 to SNMP Custom MIB

Metasys N2 and SNMP Custom MIB. The Metasys N2 by Johnson Controls network supports communications with a diverse range of devices. The SNMP driver allows the FieldServer to transfer data to and from devices over Ethernet using the SNMP version 1 ...
SKU:
FS-QS-1XX0-0150
Max Points
Max Points: 250, 500
Metasys N2 to SNMP Custom MIB
This product is only available upon request Contact us now for a quote

Metasys N2 to SNMP Custom MIB


Quickserver Gateway (Serial-Ethernet)

QuickServer is a high performance, fully configurable, cost effective Building and Industrial Automation gateway for integrators to easily interface devices to networks in commercial buildings and industrial plants.

System integrators world-wide have benefitted from the value of the powerful line of interoperability gateways offered by FieldServer. Now, QuickServer adds to that value by running the same robust FieldServer protocol conversion software on a highly cost effective platform backed by the experience, engineering expertise and proven technical support that integrators have come to expect from FieldServer.

QuickServer is available in two series. The FS-QS-10XX Series is preloaded with two BAS drivers (serial, Ethernet and/or LonWorks) from a choice of Modbus RTU, Modbus TCP, BACnet/IP®, BACnet MS/TP, LonWorks®, JCI Metasys® N2 and SNMP. Each QuickServer can handle up to 250 points.

The FS-QS-12XX Series QuickServer is available to use any Serial, Ethernet or LonWorks driver in the extensive FieldServer driver library. The FS-QS-12XX Series can handle up to 500 points and is available with a choice of RS-485, RS-232 or RS- 422 serial ports, KNX or M-Bus, in addition to Ethernet and LonWorks (optional).

Each QuickServer includes browser-based tools to make it easy to set-up QuickServer and perform diagnostics including determination of status, network settings, node information, map descriptors and more. The USB flash drive also includes the Discovery utility to determine what FieldServers are on a network.

SNMP-Custom

The SNMP driver allows the FieldServer to transfer data to and from devices over Ethernet using the SNMP version 1 protocol. The FieldServer can emulate either a Server (SNMP Agent) or Client.

Max Nodes Supported:

The Client can be configured to read values specified by their SNMP Object Identifiers (OID’s), which are defined in the MIB file (Management Information Base) of the target device. When acting as an SNMP Agent (Server), the driver makes the contents of specified integer data arrays available to any SNMP Client.

The FieldServer MIB file sets out the OIDs to use. The current version of the driver can send and receive SNMP traps.

The following SNMP data types are supported:

• INTEGER

• OCTET_STREAM

• TIMER_TICKS

• STRING

The maximum number of traps currently supported is 255. The FieldServer Enterprise ID is 6347. MIB files are generated automatically from the FieldServer configuration files. A selection of standard MIB-2 OIDs are supported to allow interaction with popular Network Management packages.

Metasys N2

The Metasys® N21 by Johnson Controls network supports communications with a diverse range of devices. Many N2 compatible devices use their own version of the protocol and care must be taken to ensure that the device of interest is covered by the FieldServer implementation.

At present the FieldServer Metasys® N2 driver will support communications with the following devices or classes of devices when acting as a Client:

  • N2Open-compliant devices. N2Open is a published N2-compatible protocol enabling 3rd party device vendors to integrate with N2.
  • VMA 1400 series (with restrictions)
  • DX9100 and XT9100

When acting as a Server the FieldServer Metasys® N2 driver can emulate an N2Open device only.

Manuals

FS-8700-19 Metasys N2 by Johnson Controls Protocol Manual
FS-8704-09 SNMP_ Manual
QuickServer Start-up Guide

Datasheets

FS-8700-19 Metasys N2 by Johnson Controls Protocol Data Sheet
FS-8704-09 SNMP_ Datasheet
QuickServer Data Sheet

Resources

Metasys N2 by JCI - ComBus Quick Tester Manual
Johnson Controls Metasys N2 Communications Interface Technical Manual
Metasys N2 by JCI - N2 Communication Bus Tech Bulletin
Metasys N2 by JCI - UNT110 UNT111 controller
Metasys N2 by JCI - checksum analysis
Metasys N2 by JCI - HVAC_PRO_help files
Metasys N2 by JCI - Device Points
Metasys N2 by JCI - DX9100 ConfigGuide
Metasys N2 by JCI - DX9100 Wiring
Metasys N2 by JCI - NAE Configuration
Metasys N2 by JCI - Metasys Unitary Controller (UNT)
Metasys N2 by JCI - vma1420
SNMP Test Software
SNMP Test Software Manual
SNMP Test Software - 2
SNMP Mib Browser
IBMs SNMP Manual
Dell - How to Secure SNMP
Fast Track Intro to SNMP
MG Mib Browser Tool
SNMP RFC1156

Block Diagrams

LP Metasys N2 Open - All Solutions
LP SNMP

Gateway Selector

Select your combination of protocols.
Protocol 1
Protocol 2

Contact Us

Contact us via phone (+1 866-383-1657) or leave a detailed message below for sales, support, or any other needs

*Required Field
I'd like to receive the newsletter. *Check email for confirmation.
*Required Field
Preferred Time To Be Contacted (PST)
8:00am - 12:00pm 12:00pm - 5:00pm