DNP3 Gateways Problem Solving



FieldServer’s are highly configurable devices and can be configured to be both DNP3 masters and slaves. In fact a single FieldServer can be configured to act as both master on one or more ports and as a slave on other ports. This allows you to use a FieldServer as a DNP3 data concentrator. One consequence of the degree of flexibility is that the FieldServer cannot be certified as compliant at any level except for a particular configuration. However, the gateway is fundamentally level 1 compliant and has most of the features and object support required for level 2 compliance.

Any data read using any of FieldServer’s over 110 protocols can be served as DNP3 data and Classes can be constructed in the configuration file to consist of the data sets you want. The driver can read and write data and poll for class data. Most qualifiers and almost all objects and variations are supported.

Convert 

We have module solutions which allow integration directly into DNP3 as well as the stand alone solutions shown bottom right.

Range of Conversion Solutions 

Depending on project requirements select from units with varying resources. and multi port devices. OEM and embedded solutions too.

FS20 Series1x RS232/4851x Ethernet1x Lonworks
FS25 Series2x RS232/4851x Ethernet
FS30 Series2x RS232 and 2x RS4852x Ethernet1x LonworksFieldBus Support:eg Profibus, DeviceNet etcHot Standby Support
FS40 Series10x RS232 and 2x RS4852x Ethernet1x LonworksFieldBus Support: eg DH+, MB+, Profibus,
DeviceNet etcHot Standby Support
SlotServer1x RS232/4851x Ethernet1x LonworksFor Rockwell ControlLogix 5600

Lonworks and Fieldbus are options not proviced on base models.

Block Diagram

FS30 series shown for purposes of illustration. Capability depends on hardware, firmware and configuration.


Chipkin Automation and DMP3

This driver was developed for FieldServer by Chipkin Automation Systems. Get expert configuration and support from day 1.

Data Sheets and Manuals

– Data Sheet – FieldServer Driver – Serial – FS-8700-47 – DNP 3.0

 Manual – FieldServer Driver – Serial – FS-8700-47 – DNP 3.0

More Data Sheets

Need Help

DNP3 Web Site: www.dnp.org

Need more info ? Call or email us.

Metasys® as used in this document is a trademark of Johnson Controls, Inc.

Gateway Selector

Select your combination of protocols.
Protocol 1
Protocol 2

Contact Us

Contact us via phone (+1 866-383-1657) or leave a detailed message below for sales, support, or any other needs

*Required Field
I'd like to receive the newsletter. *Check email for confirmation.
*Required Field
Preferred Time To Be Contacted (PST)
8:00am - 12:00pm 12:00pm - 5:00pm