CAS 2700-02B Veeder-Root Gateway

Veeder-Root Serial and TCP to BACnet IP, Modbus TCP / RTU, and Web Gateway.
SKU:
CAS2700-02
Max Points
Max Points: 250, 500
CAS gateway 800 BLACK no Background -

The CAS 2700-02 Veeder-Root Gateway can poll Veeder-Root TLS Panels for status, real-time, and configuration data. The Gateway can be used to read Tank Inventory, System Status, Tank Alarms, Sensor Alarms and more. The Veeder Gateway serves data from a TLS panel as Modbus, BACnet or Web data. The gateway supports all these options simultaneously. Use the data you want and ignore the other.

The Gateway connects to the TLS Panel, reads data and stores it internally. When a remote system requests data, this data is served in a form that is appropriate to the protocol. In the event that the connection to the TLS Panel is lost, or data cannot be read, the gateway can signal this to the remote data client.

The gateway requires minimal configuration and can be considered a plug and play component of a system, in that it is ready to operate out of the box with the default configuration. The Veeder-Root drivers support using a RS232 serial port or TCP/IP Ethernet to connect between the Gateway and the TLS Panel. The Panel therefore must have a suitable RS232 card or Ethernet card installed.

Supported Veeder-Root TLS350 Commands

The following is a list of the Veeder-Root TLS350 Protocol Commands that the CAS 2700-02 Gateway supports:

  • 101 - System Status Report
  • 201 - In-Tank Inventory Report
  • 202 - In-Tank Delivery Report
  • 301 - Liquid Sensor Status Report
  • 406 - Relay Status Report
  • B38 - Vacuum Sensor Diagnostic Report

Note: The CAS 2700-02 Veeder-Root Gateway does not support any functions that can configure or change settings on the Veeder-Root panels. As such, all data points that the Gateway makes available via Modbus, BACnet, and Web requests are read-only.

Supported Modbus TCP/RTU Commands

The CAS 2700-02B Veeder-Root Gateway supports the following Modbus TCP/RTU commands:

  • 01 (0x01) Read Coils
  • 02 (0x02) Read Discrete Inputs
  • 03 (0x03) Read Holding Registers
  • 04 (0x04) Read Input Registers
  • 05 (0x05) Write Single Coil
  • 06 (0x06) Write Single Register
  • 15 (0x0F) Write Multiple Coils
  • 16 (0x10) Write Multiple Registers
Supported BACnet IP Commands

The CAS 2700-02 Veeder-Root Gateway executes, or responds to, the following BACnet IP commands:

  • Who-Is
  • Who-Has
  • ReadProperty
  • ReadPropertyMultiple
  • WriteProperty
  • WriteProperptyMultiple
  • SubscribeCOV
  • TimeSynchronization
Supported Veeder-Root products

The CAS Veeder-Root Gateway supports the following Veeder-Root Products:

  • TLS-450 PLUS Automatic Tank Gauge
  • TLS4i / TLS4c Automatic Tank Gauge
  • TLS-350 Automatic Tank Gauge
  • TLS-350 Plus Automatic Tank Gauge
  • TLS-350R Automatic Tank Gauge
  • TLS-300C/I Automatic Tank Gauges
  • TLS-2/P Automatic Tank Gauge

Specifications

CAS Hardware 700

The following specifications are common to all Chipkin gateways.

  • Certifications: UL and ULc approved
  • Ports:
    • 10/100BASE-T with RJ-45 connector
    • 1x RS232 port
    • 1x RS485 port (different models have additional ports)
  • Power: 7 – 24 VDC through an external power supply. (12V @ 90mA)
  • Operating temperature: 0 – 70 °C (32 – 158 °F)
  • LEDs: link, speed/data, power

Dimensions
  • Dimensions (LxWxH): 107 x 83 x 25 mm (4.2 x 3.25 x 1 in.)
  • Connection type: RS485 (jumper change to RS232)

Top


Bottom


Block Diagrams

/2017/aug/01-13-08-07_CAS2700-02B_blockDiagram.png

Resources

All CAS 2500, 2700, 2800 products

A quick start guide with instructions for some of the basic operations of the CAS Gateway product line. Includes instructions for the following:

  • Detecting the CAS Gateway via the computer and settings its IP Address
  • Downloading the Firmware to the CAS Gateway
  • Downloading the Assets to the CAS Gateway
  • Downloading the Configuration to the CAS Gateway

Veeder-Root

The default configuration for a CAS 2700-02B Veeder-Root Gateway. 

All CAS 2500, 2700, 2800 products

A quick start guide with instructions for some of the basic operations of the CAS Gateway product line. Includes instructions for the following:

  • Detecting the CAS Gateway via the computer and settings its IP Address
  • Downloading the Firmware to the CAS Gateway
  • Downloading the Assets to the CAS Gateway
  • Downloading the Configuration to the CAS Gateway

Additional Information

CAS Veeder Root Serial Connectors


CAS Veeder Root Quick Assembly Cable


Gateway Selector

Select your combination of protocols.
Protocol 1
Protocol 2

Related Products

Contact Us

Contact us via phone (+1 866-383-1657) or leave a detailed message below for sales, support, or any other needs

*Required Field
I'd like to receive the newsletter. *Check email for confirmation.
*Required Field
Preferred Time To Be Contacted (PST)
8:00am - 12:00pm 12:00pm - 5:00pm