Discontinued! Modbus RTU to Modbus TCP Soft Gateway

Replaced by MODBUS TO BACNET QUICKSERVER GATEWAY. Modbus RTU to Modbus TCP Windows Gateway acts as a software-based protocol converter. It converts Modbus RTU data and allows it to work on a Modbus TCP Network.
The Modbus RTU driver allows the Gateway to transfer data to and from devices via a serial RS485 connection using the Modbus protocol.
The Modbus TCP driver allows the Gateway to transfer data to and from devices over Ethernet TCP/IP using the Modbus protocol.
SKU:
CAS-3000-07
Windows -

Replaced by MODBUS TO BACNET QUICKSERVER GATEWAY. Chipkin's Modbus RTU to Modbus TCP Software Gateway is a Windows-based protocol converter. The gateway operates by reading the data from Modbus RTU devices. The values read from these sensors then can be read from a Modbus TCP network.

The gateway requires minimal configuration and can be considered a "plug and play" component of any network system. It's ready to operate out of the box and can be installed without an engineer's approval.

CAS2500 - Windows

This device is a Software version of our Data Client/Logger and Gateway. It is compatible with an hardware that can load Windows 7 or 10. It allows you to turn any PC that meets the minimum requirements into a Data Client/Logger and Gateway.

Modbus RTU Driver

The CAS Modbus RTU driver allows the CAS Gateway to transfer data to and from devices via a serial RS485 connection using the Modbus protocol.  The CAS Gateway can either be a Client, reading and controlling values from a slave, or a Server, serving data to a Modbus Master.

The CAS Modbus RTU Driver supports the following Modbus Functions:

- 01 (0x01) Read Coils- 05 (0x05) Write Single Coil
- 02 (0x02) Read Discrete Inputs- 06 (0x06) Write Single Register
- 03 (0x03) Read Holding Registers- 15 (0x0F) Write Multiple Coils
- 04 (0x04) Read Input Registers- 16 (0x10) Write Multiple Registers

Modbus TCP Driver

The CAS Modbus TCP driver allows the CAS Gateway to transfer data to and from devices over Ethernet TCP/IP using the Modbus protocol.  The CAS Gateway can either be a Client, reading and controlling values from a slave, or a Server, serving data to a Modbus Master.

The CAS Modbus TCP Driver supports the following Modbus Functions:

- 01 (0x01) Read Coils - 05 (0x05) Write Single Coil
- 02 (0x02) Read Discrete Inputs- 06 (0x06) Write Single Register
- 03 (0x03) Read Holding Registers    - 15 (0x0F) Write Multiple Coils
- 04 (0x04) Read Input Registers- 16 (0x10) Write Multiple Registers
I'd like to inquire about the Discontinued! Modbus RTU to Modbus TCP Soft Gateway CAS-3000-07. Please provide me with a quote for this product.

Specifications

CAS2500 - Windows

Minimum Requirements:

  • Operating systems: Windows 7, Windows 10 
  • >= 10 mb disk space 
  • >= 512 mb ram 
  • Ethernet network adapter 

If RS232 or RS485 serial connection is needed, an adapter will be required. Chipkin Automation systems suggest ACON U-01.

Block Diagrams

Additional Information

CAS 2500/2700 RS485 Connector




Image result for rs485 2 wire to 4 wire