FieldServer ProtoAir Vodafone LTE wireless gateway

AT&T Cellular and Wi-Fi Gateway.
The FieldServer ProtoAir LTE wireless gateway provides the Equipment Manufacturer (OEM) a cost-effective interface to Building Management Systems (BMS) and immediate IoT remote monitoring capabilities for all devices in the field at no extra cost.
SKU:
FPA-C43-XXXX
ProtoAir FPA-C4X - ProtoAir FPA-C4X

Serial, Ethernet, AT&T Vodafone and Wi-Fi 

ProtoAir cellular gateways

The FieldServer ProtoAir LTE wireless gateway provides the Equipment Manufacturer (OEM) a cost-effective interface to Building Management Systems (BMS) and immediate IoT remote monitoring capabilities for all devices in the field at no extra cost.

Integrated MSA Grid cloud platform support enhances the ProtoAir LTE’s value by enabling remote monitoring, control, cloud-based alarm notifications (SMS or E-Mail) for trouble or alarm conditions and data visualization. MSA Grid - FieldServer Manager users can view data, download historical data and provide remote monitor/control for any connected devices. Additionally, a FieldServer Manager integrated ProtoAir LTE dramatically reduces the time for an OEM to implement their IoT cloud strategy.

The ProtoAir FPA-C4X uses LTE to securely connect devices to AT&T, Verizon or Vodafone networks. This cellular connection allows IoT applications to move machine data into the cloud for maintenance, management and troubleshooting of remote equipment. An embedded OpenVPN Server enables secure remote access and programming of the OEMs Ethernet devices in the field.

I'd like to inquire about the FieldServer ProtoAir Vodafone LTE wireless gateway FPA-C43-XXXX. Please provide me with a quote for this product.

Specifications

ProtoAir cellular gateways
Environment
  • Operating Temperature: -20 to 70°C (-4 to 158oF)
  • Relative Humidity: 10-95% RH non-condensing
Power Requirements
  • Intput: 24VAC 0.125A, 9-30VDC 0.25A @12 VDC
  • Max Power: 3W
Physical Dimensions
  • Dimensions (WxDxH): 4 x 1.1 x 2.7 in (10.16 x 2.8 x 6.8cm)
  • Weight: 0.4 lbs (0.2 Kg)
Wi-Fi 802.11 b/g/n
  • Frequency: 2.4 GHz
  • Channels: 1 to 11 (inclusive)
  • Antenna Type: MSA
  • Encryption: TKIP, WPA2 & AES
Communication

FPA-W44:

  • Baud: 9600, 19200, 38400, 57600, 76800, 115000
  • Serial (Galvanic Isolation) Ports: 1 x RS485, 1 x RS232/RS485
  • Ethernet Port: 10/100baseT, MDIX, DHCP

FPA-C4X

  • Baud: 9600, 19200, 38400, 57600, 76800, 115000
  • Serial (Galvanic Isolation) Ports: 1 x RS485, 1 x RS232/RS485
  • Ethernet Port: 10/100baseT, MDIX, DHCP
Other

Web configuration
On-board diagnostics
DIN rail mount included

Cellular Frequencies Supported
  • NA AT&T LTE: 700(B17/B12/B13) / 850(B5) / AWS1700(B4) / 1900(B2)
  • NA Verizon LTE: 700(B13) / AWS1700(B4) / 1900(B2)
  • EU LTE: 800(B20) / 900(B8) / 1800(B3) / 2100(B1) / 2600(B7) Rx Diversity and MIMO DL 2x2
  • Antenna Type: MSA
  • Encryption: TKIP, WPA2 & AES
Approvals
  • UL UL 62368-1
  • BTL marked and PTCRB and UKCA compliant
  • CE and FCC Class Part 15 C
  • RoHS3 and WEEE compliant
  • CE and FCC Class B & C Part 15
  • DNP 3.0 and Modbus conformance tested
  • ODVA CONFORMANT

Block Diagrams

ProtoAir LTE FPA-C4X - Block Diagram

Contact Us

Contact us via phone (+1 866-383-1657) or leave a detailed message below for sales, support, or any other needs

*Required Field
*Required Field
I'd like to receive the newsletter. *Check email for confirmation.
*Required Field
8:00am - 12:00pm 12:00pm - 5:00pm