Nohmi Multicrest to Other (Any Protocol) QuickServer Gateway

The Nohmi Multicrest to Other (Any Protocol) Gateway acts as a protocol converter. It provides an easy integration of Nohmi Multicrest devices on any network.
The premium Dual QuickServer, FS-QS-3X10 series, comes equipped with dual Ethernet ports with increased security and Power.
The Nohmi Multicrest driver is a passive client driver intended for connection to the serial port of a Nohmi FACP.
"Other" represent any protocol, give us a call, we will develop the driver if we not already have it.
SKU:
CAS-QS-3010-3169 (250 points),CAS-QS-3110-3169 (500 points),CAS-QS-3210-3169 (1000 points),CAS-QS-3310-3169 (3000 points),CAS-QS-3410-3169 (5000 points),CAS-QS-3510-3169 (10000 points);
CAS-QS-2010-3169 (250 points),CAS-QS-2110-3169 (1000 points),CAS-QS-2210-3169 (500 points),CAS-QS-2310-3169 (3000 points),CAS-QS-2410-3169 (5000 points);
CAS-QS-1010-3169 (250 points);

Dual Ethernet Port Quickserver Gateway (Serial-Ethernet)

The Dual port QuickServer takes the QuickServers to the next level with Security and Power. With two Ethernet ports, the Dual port QuickServer allows data to move seamlessly across disparate subnets, using a dedicated port for Cloud connectivity. This port isolation allows for enhanced LAN security from the BMS/WAN/Cloud. An embedded OpenVPN Server enables secure remote access to Ethernet devices in the field.

The QuickServer FS-QS-3X10-F series is available at four different point capacities. Each QuickServer is preloaded with 140 different drivers, such as Modbus, BACnet, SNMP, EtherNet/IP and many more. See page 3 for the complete list. The FS-QS-3010-F can support up to 250 points. The FS-QS-3110-F can support up to 500 points. The FS-QS-3210-F can support up to 1,000 points. The FS-QS-3310-F can support up to 3,000 points. The FS-QS-3410-F can support up to 5,000 points. The FS-QS-3510-Fire can support up to 10,000 points.

Other

Can't find the protocol you are looking for? Give us a call. We regularly add new drivers to our protocol library and may already support what you are looking for. Even if we do not currently support it, we develop custom drivers on demand. Give us a call, we can write drivers for just about any device.

Below is a list of potential Protocols. Many of them, we already have and the rest, we can develop.

Allen-Bradley CSP, Armstrong FA403, ATMI ACM and TGM, BACnet Arcnet, Barrington MicroSTAR, Barrington LanSTAR, Canatal, Caterpillar, ControlNet, Cummins, Data Highway Plus (DH), Data Highway Plus (DH+), DeviceNet, DF1, DNP3, Edwards, Federal Signal Ultravoice, Fike Cheetah, Gamewell FCI, GE SNP (SNPx), GE SRTP, GE TLC, GE-EGD, HTTP, KNX, Kohler, M-Bus, McQuay Microtech, MetOne Particle Counters, Mircom FX2000, Modbus ASCII, Modbus Plus (MB), Modbus Plus (MB+), Multistack Compu25, National Time and Signal, Notifer 320/640, Notifer Legacy Panels, Notifier 3030, Omron FINS, OPC, Optomux Opto22, Profibus, Rapid Engineering ICSII, SIA Security Industry, Siemens Fire Safety, Silent Knight Fire, SNMP, Stulz, TAC I-Net, Telnet, TL1, TOA VS900, XML, Cleaver-Brooks Hawk, Carrier DataLink, EST3 Serial, Veeder Root, DNP 3.0, Mudbus Jbus, Profibus DP Slave, Notifier INA, Data Aire DAP, Data Aire DART, Secutron, RussElectric Model 2000, Notifier Italia AM6000, Notifier 200/300/400, Lutron Machine, Gardner Denver, Grinnell TFX Minerva, Modbus Tek-Air, Hochiki Serial Driver, Notifier 1010/2020, Zellweger Infratox, Notifier NCA, Notifier Onyx 640, Metasys N2, BACnet PTP Serial


Nohmi Multicrest

The Nohmi Multicrest driver is a passive client driver intended for connection to the serial port of a Nohmi FACP. A passive client driver waits for messages to be sent to it (by the panel). The driver cannot send messages to the panel and hence it cannot request the state of any point in the panel.

The driver can process alarm and trouble events, system troubles and some other messages from the panel. The driver can only be used as a client. Minimal server functionality is provided only to support our ongoing quality assurance program by facilitating automated testing of the driver. Server operation is not documented or supported.

I'd like to inquire about the Nohmi Multicrest to Other (Any Protocol) QuickServer Gateway CAS-QS-xxx0-3169. Please provide me with a quote for this product.

Specifications

FS-QS-3XX0, FS-QS-2XX0

Environment

  • Operating Temperature: -20 to 70°C (-4 to 158°F)
  • Relative Humidity: 10-95% RH non-condensing

Power Requirements

  • Input: 24VAC 0.125A, 9-30VDC 0.25A @12 VDC
  • Max Power: 3W

Physical Dimensions

  • Dimensions (WxDxH): 4 x 1.1 x 2.7 in (10.16 x 2.8 x 6.8cm)
  • Weight: 0.4 lbs (0.2 Kg)

Other

Web configuration
On-board diagnostics
DIN rail mount included

Communication

FS-QS-3XX0

  • Baud: 9600, 19200, 38400, 57600, 76800, 115000
  • Serial (Galvanic Isolation): 1 x RS-485/RS-232 & 1 x RS-485
  • Ethernet: 2 x 10/100BaseT, MDIX, DHCP for Dual, 1 x for Single

Approvals

  • CE and FCC Class B & C Part 15
  • BTL Marked
  • UL 60950-1 and CAN/CSA C22 2
  • IC Canada & KC Certification
  • RoHS3 and WEEE complaint

QuickServer Certifications

Block Diagrams

imports/blockDiagrams/LP Nohm Multicresti.jpg

Contact Us

Contact us via phone (+1 866-383-1657) or leave a detailed message below for sales, support, or any other needs

*Required Field
*Required Field
I'd like to receive the newsletter. *Check email for confirmation.
*Required Field
8:00am - 12:00pm 12:00pm - 5:00pm
Message Sent Successfully