FieldServer Driver List

Comprehensive Connectivity Solutions

Chipkin's extensive driver list covers over 150 protocols, ensuring seamless integration and connectivity across various industries and applications. Whether you need to connect to web servers, building automation systems, industrial equipment, fire alarm panels, HVAC systems, or custom devices, Chipkin has you covered. Our drivers are designed to facilitate communication and interoperability, making it easier to manage and monitor your systems efficiently.

Versatile and Customizable

In addition to our vast library of existing drivers, we also offer custom driver development tailored to your specific needs. This ensures that even the most unique or proprietary systems can be integrated into your network. From transportation and fuel management systems to lighting control and general-purpose data logging, our solutions are versatile and adaptable. Chipkin's commitment to expanding our driver offerings means that we can support an ever-growing range of protocols, providing you with the tools you need to succeed in any environment.

Below is a list of some of our drivers:

Connect to anything: Some of our drivers

Web
  • Webserver
  • XML
  • SNMP
  • TELNET

Building Automation

  • KNX
  • Lonworks
  • BACnet IP
  • BACnet Ethernet
  • BACnet MSTP
  • BACnet Arcnet
  • BACnet PTP
  • Metasys N2
  • TAC Inet

Industrial

  • OPC for Scada / HMI
  • Modbus (Full family of protocols)
    • RTU and Jbus
    • TCP/IP
    • MB+
    • Daniels
  • Rockwell (Full family of protocols)
    • DF1
    • DH+
    • Ethernet/IP
    • CSP (Legacy Ethernet)
    • ControlNet
  • GE-Fanuc (Full family of protocols)
    • SNP
    • SNPx
    • EGD
    • SRTP
    • GE Mark IV
    • GE TLC
  • Siemens
  • Omron Fins
  • DNP3
  • Opto22
  • Profibus
  • DeviceNet

Fire Alarm Panels

  • Notifier AM200,300,400,600
  • Notifier 1010/2020
  • Notifier INA
  • Notifier 640
  • Notifier 3030 version 2
  • Notifier 3030
  • Notifier NCA
  • Notifier AM60000
  • Notifier Italia
  • Simplex 4100
  • Siemens Fire Safety MXL or XLS
  • Grinnell
  • Fike Cheetah
  • Vesda
  • FCI 7200 series
  • FCI 7100 series
  • FCI E3 series
  • Grinnell TFX Minerva
  • Silent Knight
  • Secutron
  • Gamewell
  • Gamewell-FCI NGA Network Graphic Annunciator
  • Edwards Quickstart
  • National Time and Signal
  • Data Aire DAP
  • Data Aire DART
  • Mircom FX2000
  • Mircom PRO2000
  • SIA
  • Protec - Safe Fire Gateways
  • Precise Time and Frequency - PTF 3702A Series

HVAC Systems

  • Strane BCU and Summit
  • WorkStation
  • Alerton
  • Delta Controls
  • Andover Controls
  • Siemens
  • Honeywell and Automation Logic
  • DataAire
  • Tek-Air
  • York Chillers
  • McQuay
  • Stulz
  • Canatal
  • Pneumatic Products ADC
  • Barber Coleman
  • Rapid Engineering
  • TAC Inet
  • Carrier – DataLink
  • Carrier – DataPort
  • Cleaver Brooks
  • York Talk
  • Barrington Microstar

  • Mitsubishi
  • Harshaw Trane

Custom

  • We can build custom drivers for your device.

Transportation and Fuel

  • Hanning & Kahl HCS-R
  • Safetran for Vital Harmon
  • Veeder Root
  • Global Software Corp

Intercom / Siren

  • Federal Signal
  • TOA Electronics

Lighting

  • Lutron Elumem
  • Lutron Zone
  • GE TLC

Others – Genset, Gas, Instrument, misc…

  • Caterpillar
  • Lutron
  • Processor Simple
  • Siemens Tiway
  • Weigh Tronix
  • Ilco  Millennium
  • Gardner Denver
  • Envirotronics
  • TL1
  • General Purpose Data Logger
  • General Purpose Ascii
  • VESDA
  • B7B Electronics
  • MetOne Particle Counters
  • Zellweger MDA 16 Gas
  • Zellweger Infratox
  • Zellweger CM4
  • Armstrong FA403
  • ATMI TGM
  • Setra 370 Pressure
  • Toshiba UPS
  • United Power UPS

… Over 110 other protocols and counting

Metasys® as used in this document is a trademark of Johnson Controls, Inc.

Contact Us

Contact us via phone (+1 866-383-1657) or leave a detailed message below for sales, support, or any other needs

*Required Field
*Required Field
I'd like to receive the newsletter. *Check email for confirmation.
*Required Field
8:00am - 12:00pm 12:00pm - 5:00pm
Message Sent Successfully