Hobart - What is the Hobart Ground Power Modbus and BACnet and HTML Gateway

CAS-2700-01

Hobart Ground Power

Modbus and BACnet and HTML Gateway


Description

The HOBART Ground Power Serial Driver allows the Gateway to poll Hobart devices for status, real time and configuration data. Thus the driver can be used to read current, voltage, phase, power and other variables from the Hobart device.

The Hobart Ground Power (HGP) Gateway serves data from a HGP controller as Modbus, BACnet or Web data. The gateway supports all these options simultaneously. Use the data you want and ignore the other.

The Gateway connects to the HGP controller, reads data and stores it internally. When a remote system requests data, this data is served in a form that is appropriate to the protocol. In the event that the connection to the HGP controller is lost, or data cannot be read, the gateway can signal this to the remote data client.

The gateway requires minimal configuration and can be considered a plug and play component of a system, in that it is ready to operate out of the box with the default configuration.

The driver is a serial driver using a RS232 serial port to connect between the Gateway and the HOBART unit.


Max Nodes Supported

Gateway Mode
NodesComments
Client1Only 1 Hobart Device per connection
Server0Not supported or documented


Connection Information

Connection type : EIA232

Baud Rates: Driver Supports : 110; 300; 600; 1200; 2400; 4800; 9600; 19200; 28800; 38400; 57600; 115200 Baud HOBARTsupports: 9600

Data Bits: Driver Supports : 7,8 HOBART supports: 8

Stop Bits: Driver Supports : 1,2 HOBART supports: 1

Parity: Driver Supports : Odd, Even, None HOBART supports: None

Hardware interface: N/A

Multidrop Capability No


Devices Tested

DeviceTested (Factory, Site)
2Hobart Model xxxxxxNot Tested
  


Connection configurations


https://cdn.chipkin.com/articles/wp-content/uploads/2012/05/Hobart1.jpg

Driver Operation

The driver can be configured to execute any of the commands in the 'supported function' list. The data sent is stored internally in the Gateway and is made available to other protocols (Modbus, BACnet and HTML).

The frequency with each data point is read is configurable. The driver retries on errors or timeouts. If the data cannot be read then after some configurable time it is marked as out of service.


Communications functions

Supported functions.

Not all Hobart communication functions are supported. Most that report status info are provided. Those used to configure the unit are not included. Please review this list in determining whether this driver is fit for your purpose.

   
COMMANDCONFIGURATION DATA 
C00DEVICE IDENTIFIER 0 CMD 
C01DEVICE IDENTIFIER 1 CMD 
C02DEVICE IDENTIFIER 2 CMD 
C03RECORD POINTER CMD 
C04MAN VOLT ADJUST ADJUST VALUE CMD 
C05LINE DROP COMP ADJUST VALUE CMD 
C06TOTAL ACCUM KILOWATTS 0 CMD 
C07TOTAL ACCUM KILOWATTS 1 CMD 
C08TOTAL ACCUM KILOWATTS 2 CMD 
C09TOTAL ACCUM KILOWATTS 3 CMD 
C10CURRENT TIME HOURS CMD 
C11CURRENT TIME MINUTES CMD 
C12CURRENT TIME SECONDS CMD 
C13CURRENT DATE YEAR CMD 
C14CURRENT DATE MONTH CMD 
C15CURRENT DATE DAY CMD 
C16PREVIOUS DATE MONTH CMD 
C17KVA RATING CMD 
C18TRANSFORMER 12 PULSE PRESENT CMD 
C19CONTACTOR SENSE NUMBER CMD 
C20RECORD OVERFLOW FLAG CMD 
C21SPARE 8 BIT 1 CONFIG CMD 
C22CURRENT LIMIT ADJUST VALUE 0 CMD 
C23CURRENT LIMIT ADJUST VALUE 1 CMD 
C24DC MAN VOLT ADJUST VALUE CMD 
C25TR CONFIGURATION CMD 
   
   
COMMANDREAL TIME DATA 
D00EVENT DESCRIPTION CMD 
D01ADVCOMM COMMAND CMD 
D02ADV FAULT CMD 
D03START TIME HOURS CMD 
D04START TIME MINUTES CMD 
D05START TIME SECONDS CMD 
D06START DATE YEAR CMD 
D07START DATE MONTH CMD 
D08START DATE DAY CMD 
D09MAX CURRENT TIME HOURS CMD 
D10MAX CURRENT TIME MINUTES CMD 
D11MAX CURRENT TIME SECONDS CMD 
D12EF WARNING CMD 
D13FRONT PANEL STATUS CMD 
D14KILOWATTS CMD 
D15OUTPUT STATUS CMD 
D16SPARE 8 BIT 4 DATA CMD 
D17SPARE 8 BIT 3 DATA CMD 
D18SPARE 8 BIT 2 DATA CMD 
D19SPARE 8 BIT 1 DATA CMD 
   
E00ELAPSED TIME MINUTES TIMER CMD 
E01PHASE A VOLTS CMD 
E02PHASE B VOLTS CMD 
E03PHASE C VOLTS CMD 
E04PHASE A B VOLTS INPUT CMD 
E05PHASE B C VOLTS INPUT CMD 
E06PHASE C A VOLTS INPUT CMD 
E07PHASE 1A AMPS CMD 
E08PHASE 1B AMPS CMD 
E09PHASE 1C AMPS CMD 
E10PHASE 2A AMPS CMD 
E11PHASE 2B AMPS CMD 
E12PHASE 2C AMPS CMD 
E13HIGHEST OUTPUT AVE AMPS CMD 
E14NEUTRAL AMPS CMD 
E15DC OUTPUT CURRENT CMD 
E16KILOWATT HOURS CMD 
E17OUTPUT FREQUENCY CMD 
E18BUS VOLTAGE CMD 
E19MAX CURRENT CMD 
E20DC OUTPUT VOLTAGE CMD 
E21SPARE 16 BIT 1 DATA CMD 


The driver will not send the next command until a response has been received from the previous or until a timeout has expired.


Support

This driver was developed by Chipkin Automation Systems (CAS). CAS are proud to provide support for the driver. For support please call CAS at (866) 383-1657.


Revision History

DateRespFormatDriver Ver.Doc. Rev.Comment
26 Aug 2010PMC 0.000Created.
21 Sep 2010PMC 0.001Updated. Replaced supported function list.