Our Devices From Your Experts in Building and Industrial Automation Protocols
Chipkin
Chipkin is a building and industrial automation protocol expert. We sell, support, develop, install, configure protocol converters/gateways, data loggers, remote monitoring and control applications.
Founded in October 2000, Chipkin focuses on machine to machine data communications and remote monitoring. Our skills and solutions include protocols like BACnet, Modbus, Veeder-Root as well as interfaces for many fire, HVAC, lighting and other systems such as Simplex, Notifier, McQuay, GE to name a few. With Chipkin, you are buying a solution, not a commodity: The combination of configuration, expertise in this field, free BACnet and other tools and support via phone, email, and remote desktop tools means Chipkin is right there with you.
Chipkin develops and sells solutions for real-life problems. We carry gateways, data clients, Stacks/Libraries, specialized tools and provide a wide range of services from consulting services to Custom solutions and site visits.
Protocol conversion Solutions
Chipkin offers a wide range of solutions. With a specialty in Building Automation and Integration, some of the products are Hunter Irrigation Solutions, OPC UA Integration Solutions, Data Clients (aka Data Loggers), BACnet Stack, Software Tools, BACnet Explorer.
Chipkin provides solutions, not boxes. We work with our clients to ensure the solution to their problems is customized to their needs. CONTACT US we are happy to provide a free consultation on your integration related project. Even if we do not carry a solution, we may be able to build one for you.
Hunter ACC and ACC2
The Hunter ACC & ACC2 protocol can be used to connect to suitably enabled Hunter Industries controllers such as the ACC99 Irrigation Controller. The Driver can read and write data, change settings and issue commands to the irrigation system.
OPC UA
The OPC UA protocol can be used to integrate OPC UA enabled devices and Networks with other protocols such as BACnet, Modbus, DNP3 etc. The Driver can fully integrate OPC UA devices into BAS and other devicves into OPC UA Systems.
Data Clients (aka Data Loggers)
A Data Client (also data logger, Datalogger or data recorder) is an electronic device that records data over time or in relation to other factors and provides this data for varying uses. Data Clients read data from field Devices and use any or all of the following features.
- Report: Display current values and status.
- Trend: Display recent readings on a rendered chart. The number of samples and other parameters are configurable.
- Log: Timestamp data and append to log files on a FIFO basis.
- Archive: Append Real-time data to archive files which are zipped to save space. Many Configurable parameters.
- Serve tp Web: Use JSON, HTTP to provide data-push services. Data can be pushed from site to the cloud and used in data visualization software.
- Serve to Enterprise: Use XML and other enterprise protocols.
- Provide Visualization: Use complex web-based GUI to animate objects with live data and create analytical charts.
Chipkin provides both Hardware versions and soft versions of our Data Loggers. Our software Data Loggers runs on any compatible version of windows. This means you can select your own computers of any format to run them on or you can run them on a server. Interested? CONTACT US
BACnet Stack
Chipkin's BACnet Stack (CAS BACnet Stack) is an application layer BACnet library for embedded systems and application development. The BACnet Stack can function both as a server (Field Device, etc…) or as a client (HMI, etc…)
The BACnet Stack is a transport layer independent library, making it easy to use with any transport layer such as MSTP, IP, Ethernet and even PTP and ARCnet. By giving you control of the transport layer, you can optimize bandwidth and performance by exploiting resources at your disposal such as multi-threading and multiple simultaneous connections.
The CAS BACnet Stack can save man-years of development when your company needs to add BACnet to their products. Interested on the BACnet Stack? Read More!
Software Tools
Chipkin Regularly develops tools to help make our job easier. Depending on the effort to run and maintain these tools, Chipkin provides them for a small fee or for free altogether. Some of our tools are the CAS BACnet Explorer, our Free Modbus Scanner, BACnet Object Monitor and Modbus Parsers Read More!
CAS BACnet Explorer
CAS BACnet Explorer is the perfect utility for testing, debugging and discovering BACnet® networks and devices. It is great for network diagnostics and discovering who is the problem. No more pointing fingers.
CAS BACnet Explorer performs the following functions within BACnet Networks:
- Exploring/Discovering
- Testing
- Debugging
- Monitoring
BACnet for Field Technicians (Free!)
Learning about BACnet? Want to update your BACnet knowledge? This free EBook will guide you through basic and advanced BACnet topics.
You can purchase a hardcopy of this book from Amazon or you can download the BACnet for Field Technicians for free from our website.


