RS-485 Trunk Scalability: Strategies Beyond 32 Devices

This article explains how many devices it is practical to place on a single RS-485 BACnet/MODBUS trunk based on electrical and protocol considerations. It provides guidelines for plann…
Read More

Adding Objects to the Monitor List in CAS BACnet Explorer

CAS BACnet Explorer: Available as a free tool for discovering, browsing…
Read More

BACnet Explorer: Change the Default BACnet Port

View Product: CAS BACnet Explorer – The Industry Standard Discovery Tool The CAS BACnet Explorer defaults to the standard…
Read More

BACnet MS/TP to Metasys N2 Data Type Mapping on QuickServer Gateways

When configuring a QuickServer Gateway to bridge data points from BACnet MS/TP to Metasys N2, the most important early step is selecting compatible point d…
Read More

Modbus/TCP to BACnet/IP Configuration Sample

Integration Solutions Chipkin has integration solutions for almost every situation. We specialize in network protocol communications and have over 20+ years of…
Read More

Understanding BACnet Objects: Concepts, Types, and Applications

BACnet object(s) are concepts that allow the communication and organization of data related to inputs, outputs, software, and calculations to be performed. The BACnet Object can manifest itself…
Read More

Visual Test Shell: Configuring Names

After configuring the Devices and Ports, the next step is to configure the Names. In the Visual Test Shell (VTS) a name is a shortcut for an address. They are use…
Read More

Visual Test Shell – First Time Use

When you want to use the Visual Test Shell (VTS) for the first time, browse to the directory where you installed the application.Double-click on the VTS.exe to start the application.You will notice t…
Read More

Visual Test Shell (VTS): Overview & Features

This article describes the Visual Test Shell (VTS), a BACnet testing and diagnostics tool. It covers key concepts, user interface elements, available features, and common tasks supported b…
Read More

Visual Test Shell – Installation

To install the Visual Test Shell (or VTS) first visit the project website at http://sourceforge.net/projects/vts/. Press the Download button to begin downloading.…
Read More

Visual Test Shell – Testing MSTP Device

In order to test a BACnet MSTP device using the Visual Test Shell (VTS) there are a few items to take into consideration.1)      The VTS will not connect to an MSTP link using an RS-485 port on a PC.2…
Read More

Why can’t I change to 76800 baud rate on PC?

A common question during serial communications troubleshooting is why a PC cannot be configured to use a baud rate of 76800, even though some industrial devices appear to support it…
Read More