Caterpillar M5X - What is Caterpillar CATM5X Protocol Driver

Integration Solutions Chipkin has integration solutions for almost every situation. We specialize in network protocol…
Read More

Cat M5X - Modbus Memory Map ECMP 3.1 3.2 3.3

This page is a technical reference for a subset of the Cat M5X (Caterpillar) generator controller EMCP 3.1, 3.2, and 3.3 Modbus memory map. In many generat…
Read More

Modbus - There are (were) a Max of 9999 points of each data type

Modbus Addressing Limits: 9,999 Points and 5-Digit vs 6-Digit Addressing A common source of confusion in Modbus projects is point numbering and “address rang…
Read More

CEI-ABI - Connection Notes

Back to Main Article: Notifier Fire Alarm Panel Integration Solutions…
Read More

TAC-I/Net - Server only

TAC-I/Net to BACnet Gateway This technical note details the s…
Read More

Veeder-Root - Printing Setup Report

Printing and saving a Veeder-Root setup report is a critical step after completing configuration of a TLS-300 or TLS-350 automatic tank gauge (ATG) s…
Read More

RS485 Cables: Why you need 3 wires for 2 (two) wire

RS485 needs 3 conductors and a shield. Many people say it's a two-wire network but it is not. Two conductors are used to carry the RS485 Differential…
Read More

What is RS485, EIA-485

EIA-485 (formerly RS-485 or RS485) is a specification for the physical layer of a network that uses the difference in voltages between two wires (Three wire) to conveys data. One polari…
Read More

RS232 - How can I know which RS-232 data lines are active

The RS-232 Mini Tester is an efficient device to connect in series with any RS-232 interface for testing a serial (RS-232) link. An example of how an RS-232 mini tester looks like is shown in figure-1…
Read More

FieldServer FS20 to ICD102A Optical Isolator

FieldServer FS20 Series: Connecting to ICD102A Optical Isolator via 2-Wire RS485 This article shows a simple, practical wiring approach for connecting a FieldServer FS20…
Read More

USB-COMI-SI-M USB-TO-OPTICAL ISOLATED RS-422/485 ADAPTER

USB-COMI-SI-M – USB-to-Optically Isolated RS-422/485 Adapter The USB-COMI-SI-M is a USB-to-serial adapter that provides a reliable, optically isolated interface f…
Read More

RS485 - What happens when 2 BACnet MSTP devices have the same device ID

I was asked this question today,What would happen if you had two BACnet MSTP devices with different MAC addresses but the same BACnet Device ID (Node ID) on the same network, and you sent a Broadcast…
Read More