Combustion Safety Controller Integration from ACL Manufacturing
Intro to ACL Combustion Safety Controllers
ACL Manufacturing is an Industry Leader in the design and fabrication of Industrial Burner / Burner Management Systems, High Efficiency/Low NoX Burners, and Flare-Stack/Incinerator Ignition Systems.
As a systems integrator, Chipkin has the capabilities to integrate many Combustion Safety Controllers from ACL. Chipkin has successfully integrated and tested many of these devices and continues to add new ones.
For more information on ACL Manufacturing, click here!
ACL Combustion Safety Controller Protocol
The ACL Combustion Safety Controllers communicate using the Modbus RTU Serial communication Protocol. Chipkin offers multiple solutions that will allow you to integrate these devices to your BACnet Networks.
Not integrating to BACnet? No problem, we offer over 120 other protocols to integrate to. Too many to list here.
Contact Us to discuss your project needs, I am sure we can make the integration process an easy experience. Not only that, but all our solutions come with Free Modbus and BACnet Software for Testing.
Chipkin Gateways for ACL Combustion Safety Controllers
The Chipkin Modbus RTU Gateway is a protocol Gateway that converts data from Modbus RTU and makes it available to devices that support a different protocol e.g. BACnet IP to BACnet MSTP, Modbus TCP, HTTP etc.
Chipkin provides both Hardware versions and Soft versions of our Gateways. Our software Gateways runs on any compatible version of windows allowing you to select your own computer of any format for the conversion or you can run them on a server.
Chipkin provides solutions, not boxes. We work with our clients to ensure the solution to their problems is customized to their needs. Interested? Read More!
QuickServers for ACL Combustion Safety Controllers
The Classic QuickServer (FS-QS-1XXX) and Upgraded QuickServer (FS-QS-2XXX) are a family of high-performance, fully configurable, and cost-effective building and industrial automation protocol gateways. They are designed for integrators to easily interface devices to networks in commercial buildings, campuses, and industrial facilities.
There are six standard models that come in basic (250 points) or enhanced (500-5000 points) and can connect to serial (RS485 and RS232), Ethernet, and/or LonWorks as well as KNX and M-Bus
Chipkin provides ACL Combustion Safety Controller gateways for a wide number of conversions. Contact Us for a free consultation.
Multiport Gateway for ACL Combustion Safety Controllers
The FS-B3510 is one of the FS-X30 Series FieldServers designed to meet the needs of any system integrator.
The FS-B30 Series brings together the powerful FieldServer driver library with state-of-the-art gateway design. It supports 1,000 points which can be upgraded to 10,000 points allowing it to easily handle just about anything with no slowdown in performance.
Chipkin provides ACL Combustion Safety Controller gateways for a wide number of conversions. Contact Us for a free consultation.
ACL Manufacturing Building Management Systems Integrated
Chipkin has configured and tested gateways for a wide range of ACL Manufacturing Products. See below for a list:

- Combustion Safety Controller - CSC400
- Combustion Safety Controller - CSC200
- Flare Stack - ACL3200
Combustion Safety Controllers
ACL provides a leading-edge Combustion Safety Controller that has burner ignition and full first-out annunciation of all the shutdown inputs such as Level, High Temperature, High/Low Gas, Remote Shutdown, Pressure, Proof of Closure, Flame Failure, Power Failure, Auxiliary 1 & 2 and more.
It also provides two independent 4-20mA Inputs (level, pressure, temperature) which can be configured as latched Low or High shutdowns. The system is designed to operate with or without a continuous pilot.

BACnet for Field Technicians (Free!)
Learning about BACnet? Want to update your BACnet knowledge? This free EBook will guide you through basic and advanced BACnet topics.
You can purchase a hardcopy of this book from Amazon or you can download the BACnet for Field Technicians for free from our website.
FREE CAS BACNET EXPLORER WITH THE PURCHASE OF A BACNET GATEWAY!
Purchase a FieldServer or CAS Gateway from us that contains any BACnet protocol and we will help you test and document the BACnet interface by providing a free full license to the CAS BACnet Explorer and a hardcopy of the BACnet booklet.
The USB key and booklet ships with the product.
Thanks for choosing Chipkin’s protocol gateways, data clients, and integration services to meet your building and industrial automation requirements!
Chipkin™ is a building and industrial automation protocol expert. We develop, configure, install and support gateways (protocol converters), data loggers and remote monitor and controlling applications. Founded in October 2000, Chipkin provides expert solutions for converting BACnet®, Modbus®, and LonWorks®—to name just a few—and enabling interfaces for HVAC, fire, siren, intercom, lighting, transportation and fuel systems. The high-quality products we offer (including those from other vendors) interface with Simplex™, Notifier™, McQuay™, GE™ and many others—so you can rest assured that we will select the most appropriate solution for your application.
With Chipkin you are buying a solution. Our configuration expertise in this field combined with free BACnet and other tools ensure your success; and our customer support via phone, e-mail, and remote desktop tools means that we’re there when you need us. Chipkin is a small responsive company, and we live or die by the quality of our service—and with offices in two-time zones—we can provide support when you need it. Give us a call now!
Customer Support
Chipkin is proud to provide support for the products we sell. For technical support, sales, and customer service, please contact us at 1 (866) 383-1657