HTTP Data to BACnet IP QuickServer Gateway

The HTTP Data to BACnet IP Gateway acts as a protocol converter. It supports an easy integration of HTTP Data devices on any BACnet IP network.
Every QuickServer includes browser-based tools for quick set-up and to perform diagnostics including determination of status, network settings, node information, map descriptors and more.
The premium Dual QuickServer, FS-QS-3X10 series, comes equipped with dual Ethernet ports with increased security and Power.
The BACnet/IP driver enables the FieldServer to facilitate data exchange with devices over Ethernet using the BACnet/IP protocol.
The HTTP Data Driver allows the FieldServer to pull values from any accessible HTTP(s) API over Ethernet, using RESTful HTTP(s) request methods.
SKU:
CAS-QS-3010-3261 (250 points),CAS-QS-3110-3261 (500 points),CAS-QS-3210-3261 (1000 points),CAS-QS-3310-3261 (3000 points),CAS-QS-3410-3261 (5000 points),CAS-QS-3510-3261 (10000 points);
CAS-QS-2010-3261 (250 points),CAS-QS-2110-3261 (1000 points),CAS-QS-2210-3261 (500 points),CAS-QS-2310-3261 (3000 points),CAS-QS-2410-3261 (5000 points);
CAS-QS-1010-3261 (250 points);

BACnet IP

The BACnet/IP driver allows the FieldServer to transfer data to and from devices over Ethernet using BACnet/IP protocol. The FieldServer can emulate either a Server or Client.

All information in a BACnet system is represented in terms of objects. The Object_Identifier is a 32-bit code that identifies the type of Object (also identified by the Object_Type Property) and its "Instance" number, which together uniquely identify the Object within its BACnet device. Theoretically, a BACnet device could have over four million Objects of a particular type. The Object_Name is a text string, which has a unique capability.

BACnet devices may broadcast queries for devices that contain Objects with a specific Object_Name. This can greatly simplify project setup.

Every BACnet device must have a Device Object, which provides details about the device and its functionalities to other networked devices. Before engaging in control communications, a BACnet device must acquire pertinent information from the Device Object of the target device. Unlike other Objects, the Instance number of the Device Object must be unique across the entire BACnet internetwork, serving as the device's distinct identifier. This uniqueness facilitates easy identification of the BACnet device during installation and operation.

Standard object types are used to hold real time data and other information. Each Object Type is referenced by a number, for example 0 represents an Analog Input. See Appendix D.1 for abbreviation list.

Each Object consists of a number of prescribed properties, the main property being the Present_Value. Objects are monitored and controlled through their properties.

Quickserver Gateway (Serial-Ethernet)

The QuickServer is a high performance, fully configurable, cost effective Building and Industrial Automation gateway for integrators to easily interface devices to networks in commercial buildings and industrial plants.

System integrators world-wide have benefitted from the value of the powerful line of interoperability gateways offered by FieldServer. Now, QuickServer adds to that value by running the same robust FieldServer protocol conversion software on a highly cost effective platform backed by the experience, engineering expertise and proven technical support that integrators have come to expect from FieldServer.

QuickServer (Serial-Ethernet) is available in two series:

The QuickServer FS-QS-2X10 series is available at four different point capacities. Each QuickServer is preloaded with two drivers (serial and/or Ethernet) from a customer’s choice of 140 different drivers, E.G. Modbus, BACnet, SNMP, EtherNet/IP and many more.

The FS-QS-2010 with 2 RS485 and 1 ethernet port can support up to 250 points. The FS-QS-2210 can support up to 500 points. The FS-QS-2310 can support up to 3,000 points. The FS-QS-2410 can support up to 5,000 points.

Equivalently the FS-QS-2020 with 1 RS485, 1 RS232 and 1 ethernet port can support up to 250 points. The FS-QS-2220 can support up to 500 points. The FS-QS-2320 can support up to 3,000 points. The FS-QS-2420 can support up to 5,000 points.

Every QuickServer includes browser-based tools to make it easy to set-up QuickServer and perform diagnostics including determination of status, network settings, node information, map descriptors and more. The USB flash drive also includes the Discovery utility to determine what FieldServers are on a network.

BTL Mark is registered to the MSA BACnet Driver for MSA QuickServer line of products

Dual Ethernet Port Quickserver Gateway (Serial-Ethernet)

The Dual port QuickServer takes the QuickServers to the next level with Security and Power. With two Ethernet ports, the Dual port QuickServer allows data to move seamlessly across disparate subnets, using a dedicated port for Cloud connectivity. This port isolation allows for enhanced LAN security from the BMS/WAN/Cloud. An embedded OpenVPN Server enables secure remote access to Ethernet devices in the field.

The QuickServer FS-QS-3X10-F series is available at four different point capacities. Each QuickServer is preloaded with 140 different drivers, such as Modbus, BACnet, SNMP, EtherNet/IP and many more. See page 3 for the complete list. The FS-QS-3010-F can support up to 250 points. The FS-QS-3110-F can support up to 500 points. The FS-QS-3210-F can support up to 1,000 points. The FS-QS-3310-F can support up to 3,000 points. The FS-QS-3410-F can support up to 5,000 points. The FS-QS-3510-Fire can support up to 10,000 points.

HTTP Data

The HTTP Data Driver allows the FieldServer to pull values from any accessible HTTP(s) API over Ethernet, using RESTful HTTP(s) request methods. The HTTP Data Driver supports pulling values from multiple HTTP(s) server endpoints.

The FieldServer is a client pulling requests from a configured URL endpoint. The FieldServer stores values to be mapped to other protocols or simply to be viewed. When configured, the configured Nodes pulling in data from URL endpoints, will extract the values based on the configured Tasks Type and Pattern, if applicable.

I'd like to inquire about the HTTP Data to BACnet IP QuickServer Gateway CAS-QS-xxx0-3261. Please provide me with a quote for this product.

Specifications

FS-QS-3XX0, FS-QS-2XX0

Environment

  • Operating Temperature: -20 to 70°C (-4 to 158°F)
  • Relative Humidity: 10-95% RH non-condensing

Power Requirements

  • Input: 24VAC 0.125A, 9-30VDC 0.25A @12 VDC
  • Max Power: 3W

Physical Dimensions

  • Dimensions (WxDxH): 4 x 1.1 x 2.7 in (10.16 x 2.8 x 6.8cm)
  • Weight: 0.4 lbs (0.2 Kg)

Other

Web configuration
On-board diagnostics
DIN rail mount included

Communication

FS-QS-3XX0

  • Baud: 9600, 19200, 38400, 57600, 76800, 115000
  • Serial (Galvanic Isolation): 1 x RS-485/RS-232 & 1 x RS-485
  • Ethernet: 2 x 10/100BaseT, MDIX, DHCP for Dual, 1 x for Single

Approvals

  • CE and FCC Class B & C Part 15
  • BTL Marked
  • UL 60950-1 and CAN/CSA C22 2
  • IC Canada & KC Certification
  • RoHS3 and WEEE complaint

QuickServer Certifications

Block Diagrams

BACnet Combined Block Diagramhttp data

Logos

imports/logos/Logo BTL Bacnet Test Lab
Logo bacnet1

Contact Us

Contact us via phone (+1 866-383-1657) or leave a detailed message below for sales, support, or any other needs

*Required Field
*Required Field
I'd like to receive the newsletter. *Check email for confirmation.
*Required Field
8:00am - 12:00pm 12:00pm - 5:00pm
Message Sent Successfully