Articles Directory: Explore Our Publications Page 53

RS232 - How do I change the CAS Gateway

With the CAS Gateway, regularly you have an RS-485 port (Port 0), an RS-232 port (Port 1), and an Ethernet port. But Port 0 can be changed from its default RS-485 configuration to an RS-232 configura…
Read More

RS232 - How can I know which RS-232 data lines are active

The RS-232 Mini Tester is an efficient device to connect in series with any RS-232 interface for testing a serial (RS-232) link. An example of how an RS-232 mini tester looks like is shown in figure-1…
Read More

FieldServer FS20 Series: Connecting to ICD102A Optical Isolator via 2-Wire RS485

This diagram shows how to connect a FieldServer FS20 series to an ICD102A optical isolator using a 2-wire RS 485 connection. FieldServers only support 2-wire connections. The datasheet for the…
Read More

USB-COMI-SI-M USB-TO-OPTICAL ISOLATED RS-422/485 ADAPTER

Wiring diagram RS485. [USB-COMi-SI-M, pin 1]  (-) Negative [USB-COMi-SI-M, pin 2]  (+) Positive [USB-COMi-SI-M, pin 5]  Ground [USB-COMi-SI-M, Sw1] OFF [USB-COMi-SI-M, Sw2] OFF [USB-COMi-SI…
Read More

RS485 - BACnet MSTP (RS485), Does cable selection does make a difference

All cables offer impedance (resistance). Some cables are designed so that the impedance is relatively independent of distance. You want one of these cables. A clue to knowing if you selected one is to…
Read More

RS485 - What happens when 2 BACnet MSTP devices have the same device ID

I was asked this question today,What would happen if you had two BACnet MSTP devices with different MAC addresses but the same BACnet Device ID (Node ID) on the same network, and you sent a Broadcast…
Read More

Lonworks - Can you show me an example of typical FieldServer / QuickServer Veeder Lonworks points

DO NOT USE THIS DATA – IT IS SUBJECT TO CHANGE AND IS PROVIDED FOR REFERENCE ONLY.The points listed and the Lonworks addresses allocated are typical. We strongly advise you not…
Read More

ModbusTCP - What do you have that can help me convert my Modbus TCP data

Convert We have module solutions which allow integration directly into Modbus TCP as well as the stand-alone solutions shown bottom right. Range of Conversion Solutions We know that project require…
Read More

ModbusTCP - What type of protocol is Modbus TCP

Modbus TCPModbus TCP is part of the Modicon's Modbus family of protocols that operates on the Ethernet TCP network layer. Modbus is an open protocol and is widely uses across building automation, inte…
Read More

Checking Communication Between Device and PC: Modbus TCP

Q: We want to check the communication between our device and personal computer, so do we need 232 communication software? See original question here: https://control.com/forums/threads/modbu…
Read More

Simplified Modbus-to-Modbus Integration with FieldServer Devices

In an assembly where the Fieldserver device is reading from a Modbus device on Modbus RTU (Serial) or Modbus TCP/IP (Ethernet), and then serving to another Modbus device on Modbus TCP/IP or Modbus RTU…
Read More

ModbusTCP - Can you give me an example of a Modbus/TCP to BACnet/IP configuration

This sample FieldServer configuration illustrates a config which reads data from a Modbus/TCP device and makes the data available as BACnet data. A remote BACnet client can read and write point…
Read More