CLCTSIx LCD Touchscreen Display
The CLCTSIx is a 7-inch diagonal, high resolution, wide-screen format, color LCD touchscreen used for interfacing with the LightSweep™ modular lighting control system. The CLCTSix uses BACnet over Ethernet to communicate with controllers on a local area network. User-created graphics allow the CLCTSIx to be completely customized for a given application.
Features
- High resolution, wide-screen display
- Touchscreen interface, no stylus required
- Attractive, modern design, install in any location
- Panel, wall, new and retrofit wallboard mounting
- Create custom graphics using GE software
- Modify controller schedules and calendars
- Display and acknowledge alarms
- Change setpoints, monitor inputs and outputs
- Multiple users and passwords for restricting access
- Supports BACnet over Ethernet communications
- Firmware can be flash loaded over the network
Application
The CLCTSIx allows operators to monitor and manage LightSweep™ modular lighting control system via the CLCBnet controller by using custom real-time graphics. Designed to be mounted in small spaces, the CLCTSIx can be wall or panel mounted in an administrative area, allowing for light monitoring, setting time schedules or changing the output level for scene control – or changing the setpoint for daylight harvesting It can also be used as a Master Switch station to control the lighting in different sections in the building using custom graphic screens representing the floor layouts.
Order the touchscreen controller and desired options with the following product numbers:
- CLCTSI1 - Operator Display
- CLCTSI2 - BACnet System Manager – allows for schedule modifications
- CLCTSI3 - Embedded WEB server – all custom screens are also available as web pages
Specifications
BACnet Device Profile
- BACnet Operator Display (B-OD) (proposed new profile)
Communication
- BACnet over Ethernet – requires the CLCBnet controller
Technology
- 32-bit ARM9 Processor @ 240MHz
- 256MB Flash Memory (~195 MB available for graphics and CLCTSI database)
- Real-time clock
- Supercapacitor for 72-hr backup of real-time clock
LCD Display
- Touchscreen LCD with 7-inch diagonal widescreen display
- High resolution 800 x 480 (WVGA), 16bit color
- ~40,000 hrs backlight lifetime
Sound
- 2-Speakers