Dual Ethernet Port Quickserver Gateway (Serial-Ethernet)
The Dual port QuickServer takes the QuickServers to the next level with Security and Power. With two Ethernet ports, the Dual port QuickServer allows data to move seamlessly across disparate subnets, using a dedicated port for Cloud connectivity. This port isolation allows for enhanced LAN security from the BMS/WAN/Cloud. An embedded OpenVPN Server enables secure remote access to Ethernet devices in the field.
The QuickServer FS-QS-3X10-F series is available at four different point capacities. Each QuickServer is preloaded with 140 different drivers, such as Modbus, BACnet, SNMP, EtherNet/IP and many more. See page 3 for the complete list. The FS-QS-3010-F can support up to 250 points. The FS-QS-3110-F can support up to 500 points. The FS-QS-3210-F can support up to 1,000 points. The FS-QS-3310-F can support up to 3,000 points. The FS-QS-3410-F can support up to 5,000 points. The FS-QS-3510-Fire can support up to 10,000 points.
Other
Can't find the protocol you are looking for? Give us a call. We regularly add new drivers to our protocol library and may already support what you are looking for. Even if we do not currently support it, we develop custom drivers on demand. Give us a call, we can write drivers for just about any device.
Below is a list of potential Protocols. Many of them, we already have and the rest, we can develop.
Allen-Bradley CSP, Armstrong FA403, ATMI ACM and TGM, BACnet Arcnet, Barrington MicroSTAR, Barrington LanSTAR, Canatal, Caterpillar, ControlNet, Cummins, Data Highway Plus (DH), Data Highway Plus (DH+), DeviceNet, DF1, DNP3, Edwards, Federal Signal Ultravoice, Fike Cheetah, Gamewell FCI, GE SNP (SNPx), GE SRTP, GE TLC, GE-EGD, HTTP, KNX, Kohler, M-Bus, McQuay Microtech, MetOne Particle Counters, Mircom FX2000, Modbus ASCII, Modbus Plus (MB), Modbus Plus (MB+), Multistack Compu25, National Time and Signal, Notifer 320/640, Notifer Legacy Panels, Notifier 3030, Omron FINS, OPC, Optomux Opto22, Profibus, Rapid Engineering ICSII, SIA Security Industry, Siemens Fire Safety, Silent Knight Fire, SNMP, Stulz, TAC I-Net, Telnet, TL1, TOA VS900, XML, Cleaver-Brooks Hawk, Carrier DataLink, EST3 Serial, Veeder Root, DNP 3.0, Mudbus Jbus, Profibus DP Slave, Notifier INA, Data Aire DAP, Data Aire DART, Secutron, RussElectric Model 2000, Notifier Italia AM6000, Notifier 200/300/400, Lutron Machine, Gardner Denver, Grinnell TFX Minerva, Modbus Tek-Air, Hochiki Serial Driver, Notifier 1010/2020, Zellweger Infratox, Notifier NCA, Notifier Onyx 640, Metasys N2, BACnet PTP Serial
Hach Ultra
This serial driver connects to a trunk of 1 or more R4800 Counters that support the R4800 protocol as defined in the R4800 Operator Manual. It is capable of reading log records and status data from each transmitter as well as being able to send commands to the counter.
The driver is capable of being linked with other FieldServer drivers to form regular FieldServer firmware that can be installed on QuickServer and other FieldServer gateways. Other drivers can access the R4800 Counter’s data and serve using other protocols such as BACnet and Modbus. The driver is an active client driver in that it poll’s for data – reading or writing data from counters. It cannot be used to simulate a R4800. Because only the client side of the protocol is implemented.
Specifications
FS-QS-3XX0, FS-QS-2XX0
Environment
- Operating Temperature: -20 to 70°C (-4 to 158°F)
- Relative Humidity: 10-95% RH non-condensing
Power Requirements
- Input: 24VAC 0.125A, 9-30VDC 0.25A @12 VDC
- Max Power: 3W
Physical Dimensions
- Dimensions (WxDxH): 4 x 1.1 x 2.7 in (10.16 x 2.8 x 6.8cm)
- Weight: 0.4 lbs (0.2 Kg)
Other
Web configuration
On-board diagnostics
DIN rail mount included
Communication
FS-QS-3XX0
- Baud: 9600, 19200, 38400, 57600, 76800, 115000
- Serial (Galvanic Isolation): 1 x RS-485/RS-232 & 1 x RS-485
- Ethernet: 2 x 10/100BaseT, MDIX, DHCP for Dual, 1 x for Single
Approvals
- CE and FCC Class B & C Part 15
- BTL Marked
- UL 60950-1 and CAN/CSA C22 2
- IC Canada & KC Certification
- RoHS3 and WEEE complaint

