Metasys N2 to SNMP Custom MIB QuickServer Gateway

Metasys N2 and SNMP Custom MIB.
Every QuickServer includes browser-based tools for quick set-up and to perform diagnostics including determination of status, network settings, node information, map descriptors and more.
The premium Dual QuickServer, FS-QS-3X10 series, comes equipped with dual Ethernet ports with increased security and Power.
The Metasys N2 by Johnson Controls network supports communications with a diverse range of devices.
The SNMP driver allows the FieldServer to transfer data to and from devices over Ethernet using the SNMP version 1 protocol. The FieldServer can emulate either a Server (SNMP Agent) or Client.
SKU:
FS-QS-3010-0150 (250 points),FS-QS-3110-0150 (500 points),FS-QS-3210-0150 (1000 points),FS-QS-3310-0150 (3000 points),FS-QS-3410-0150 (5000 points),FS-QS-3510-0150 (10000 points);
FS-QS-2010-0150 (250 points),FS-QS-2110-0150 (1000 points),FS-QS-2210-0150 (500 points),FS-QS-2310-0150 (3000 points),FS-QS-2410-0150 (5000 points);
FS-QS-1010-0150 (250 points);

Quickserver Gateway (Serial-Ethernet)

The QuickServer is a high performance, fully configurable, cost effective Building and Industrial Automation gateway for integrators to easily interface devices to networks in commercial buildings and industrial plants.

System integrators world-wide have benefitted from the value of the powerful line of interoperability gateways offered by FieldServer. Now, QuickServer adds to that value by running the same robust FieldServer protocol conversion software on a highly cost effective platform backed by the experience, engineering expertise and proven technical support that integrators have come to expect from FieldServer.

QuickServer (Serial-Ethernet) is available in two series:

The QuickServer FS-QS-2X10 series is available at four different point capacities. Each QuickServer is preloaded with two drivers (serial and/or Ethernet) from a customer’s choice of 140 different drivers, E.G. Modbus, BACnet, SNMP, EtherNet/IP and many more.

The FS-QS-2010 with 2 RS485 and 1 ethernet port can support up to 250 points. The FS-QS-2210 can support up to 500 points. The FS-QS-2310 can support up to 3,000 points. The FS-QS-2410 can support up to 5,000 points.

Equivalently the FS-QS-2020 with 1 RS485, 1 RS232 and 1 ethernet port can support up to 250 points. The FS-QS-2220 can support up to 500 points. The FS-QS-2320 can support up to 3,000 points. The FS-QS-2420 can support up to 5,000 points.

Every QuickServer includes browser-based tools to make it easy to set-up QuickServer and perform diagnostics including determination of status, network settings, node information, map descriptors and more. The USB flash drive also includes the Discovery utility to determine what FieldServers are on a network.

BTL Mark is registered to the MSA BACnet Driver for MSA QuickServer line of products

Dual Ethernet Port Quickserver Gateway (Serial-Ethernet)

The Dual port QuickServer takes the QuickServers to the next level with Security and Power. With two Ethernet ports, the Dual port QuickServer allows data to move seamlessly across disparate subnets, using a dedicated port for Cloud connectivity. This port isolation allows for enhanced LAN security from the BMS/WAN/Cloud. An embedded OpenVPN Server enables secure remote access to Ethernet devices in the field.

The QuickServer FS-QS-3X10-F series is available at four different point capacities. Each QuickServer is preloaded with 140 different drivers, such as Modbus, BACnet, SNMP, EtherNet/IP and many more. See page 3 for the complete list. The FS-QS-3010-F can support up to 250 points. The FS-QS-3110-F can support up to 500 points. The FS-QS-3210-F can support up to 1,000 points. The FS-QS-3310-F can support up to 3,000 points. The FS-QS-3410-F can support up to 5,000 points. The FS-QS-3510-Fire can support up to 10,000 points.

Metasys N2

The Metasys® N21 by Johnson Controls network supports communications with a diverse range of devices. Many N2 compatible devices use their own version of the protocol and care must be taken to ensure that the device of interest is covered by the FieldServer implementation.

At present the FieldServer Metasys® N2 driver will support communications with the following devices or classes of devices when acting as a Client:

  • N2Open-compliant devices. N2Open is a published N2-compatible protocol enabling 3rd party device vendors to integrate with N2.
  • VMA 1400 series (with restrictions)
  • DX9100 and XT9100

When acting as a Server the FieldServer Metasys® N2 driver can emulate an N2Open device only.

SNMP-Custom

The SNMP driver allows the FieldServer to transfer data to and from devices over Ethernet using the SNMP version 1 protocol. The FieldServer can emulate either a Server (SNMP Agent) or Client.

Max Nodes Supported:

The Client can be configured to read values specified by their SNMP Object Identifiers (OID’s), which are defined in the MIB file (Management Information Base) of the target device. When acting as an SNMP Agent (Server), the driver makes the contents of specified integer data arrays available to any SNMP Client.

The FieldServer MIB file sets out the OIDs to use. The current version of the driver can send and receive SNMP traps.

The following SNMP data types are supported:

• INTEGER

• OCTET_STREAM

• TIMER_TICKS

• STRING

The maximum number of traps currently supported is 255. The FieldServer Enterprise ID is 6347. MIB files are generated automatically from the FieldServer configuration files. A selection of standard MIB-2 OIDs are supported to allow interaction with popular Network Management packages.

I'd like to inquire about the Metasys N2 to SNMP Custom MIB QuickServer Gateway FS-QS-XXX0-0150. Please provide me with a quote for this product.

Specifications

FS-QS-3XX0, FS-QS-2XX0

Environment

  • Operating Temperature: -20 to 70°C (-4 to 158°F)
  • Relative Humidity: 10-95% RH non-condensing

Power Requirements

  • Input: 24VAC 0.125A, 9-30VDC 0.25A @12 VDC
  • Max Power: 3W

Physical Dimensions

  • Dimensions (WxDxH): 4 x 1.1 x 2.7 in (10.16 x 2.8 x 6.8cm)
  • Weight: 0.4 lbs (0.2 Kg)

Other

Web configuration
On-board diagnostics
DIN rail mount included

Communication

FS-QS-3XX0

  • Baud: 9600, 19200, 38400, 57600, 76800, 115000
  • Serial (Galvanic Isolation): 1 x RS-485/RS-232 & 1 x RS-485
  • Ethernet: 2 x 10/100BaseT, MDIX, DHCP for Dual, 1 x for Single

Approvals

  • CE and FCC Class B & C Part 15
  • BTL Marked
  • UL 60950-1 and CAN/CSA C22 2
  • IC Canada & KC Certification
  • RoHS3 and WEEE complaint

QuickServer Certifications

Block Diagrams

MetasysN2-Block-Diagramimports/blockDiagrams/LP SNMP.jpg

Additional Information

FS-8704-09 – SNMP

Driver Version: 1.03

Document Revision: 2

FieldServer Driver – Ethernet

FS-8704-09

SNMP

Description

The SNMP driver allows the FieldServer to transfer data to and from devices over Ethernet using the SNMP version 1 protocol. The FieldServer can emulate either a Server (SNMP Agent) or Client.

The Client can be configured to read values specified by their SNMP Object Identifiers (OID’s), which are defined in the MIB file (Management Information Base) of the target device.  When acting as an SNMP Agent (Server), the driver makes the contents of specified integer data arrays available to any SNMP Client.  The FieldServer MIB file sets out the OID’s to use.

The current version of the driver can send and receive SNMP traps. The following SNMP data types are currently supported:

  • · INTEGER
  • · OCTET_STREAM
  • · TIMER_TICKS
  • · STRING

The maximum number of traps currently supported is 255.

The FieldServer Enterprise ID is 6347.  MIB files are generated automatically from the FieldServer configuration files. A selection of standard MIB-2 OID’s are supported to allow interaction with popular Network Management packages.

FieldServer Mode Nodes Comments
Client 25 Each Node is specified by a unique IP address
Server 1 As a Server the SNMP driver can act as a single Node only

Formal Driver Type

Ethernet

Client (Active or Passive) or Server


Compatibility Matrix

FieldServer Model Compatible with this driver
FS-x2010 Yes
FS-x2011 Yes
FS-x25 Yes
FS-x30 Yes
FS-x40 Yes
SlotServer Yes

Connection Information

Connection type: Ethernet
Ethernet Speeds Supported 10Base-T, 100Base-T[1]

 

Devices Tested

Device Tested (FACTORY, SITE)
MG-Soft MIB Browser and Trap Ringer Factory
Visual MIBrowser Pro from NuDesign Factory


Connection Configurations

1. FieldServer as SNMP Agent (Server)

8704-09-connection

2. FieldServer as SNMP Client

8704-09-connection

Connection Notes

1. TCP/IP Configuration: Ensure that the FieldServer and all Nodes to be monitored via SNMP have the same Netmask setting.

2. Default IP ports

  • Port 161 – Poll/Walk commands
  • Port 162 – Traps

Communications Functions - Supported Functions at a Glance:

Data Types Supported

FieldServer Data Type Description (or Device Data Type)
INTEGER
OCTET_STREAM Character strings
TIMER_TICKS Timer values in 1/100ths of a second


MIB-2 Variables Supported

Many Network Management systems poll these variables to connect to the SNMP Agent.

OID Description (or Device Data Type)
1.3.6.1.2.1.1.1 sysDescr
1.3.6.1.2.1.1.2 sysObjectID
1.3.6.1.2.1.1.3 sysUpTime
1.3.6.1.2.1.1.4 sysContact
1.3.6.1.2.1.1.5 sysName
1.3.6.1.2.1.1.6 sysLocation
1.3.6.1.2.1.1.7 sysServices


Read Operations Supported 

FieldServer as a Client FieldServer as a Server
SNMP Get Request SNMP Get Request
SNMP GetNext Request / SNMP Walk ( SNMP GetNext Request / SNMP Walk

 

Write (Control) Operations Supported

FieldServer as a Client FieldServer as a Server
SNMP Set Request SNMP Set Request

 

Unsolicited Operations Supported

FieldServer as a Client FieldServer as a Server
Receive Traps specified by OIDData stored by matching OID or by using OID string values to form lookup string. Send Traps specified by OIDTrap sent based on data change rules, periodic or on source data update.


Unsupported Functions and Data Types 

Useful Links

Logos

Logo JCI - Metasys N2
Logo SNMP
27-18-40-00 Logo SNMP
Logo SNMPv2c

Contact Us

Contact us via phone (+1 866-383-1657) or leave a detailed message below for sales, support, or any other needs

*Required Field
*Required Field
I'd like to receive the newsletter. *Check email for confirmation.
*Required Field
8:00am - 12:00pm 12:00pm - 5:00pm
Message Sent Successfully
Data Types Reason
Only the following SNMP Data Types are supported:INTEGER

OCTET_STREAM

TIMER_TICKS

STRING

Further types will be implemented as required.