Notifier Integration Solutions

NotifierSolutionImage1.gif

There are two ways we can help you with Omron FINS. Firstly we can help you connect foreign systems to your Omron PLC such as fire alarm systems, gas sensors, HVAC equipment, building automation systems etc. This way you can use your PLC's to control and monitor these devices without having to implement a hard wired solution. Secondly we can help your control or building automation system monitor and control data in an Omron PLC. In both modes our gateway can act as a client and server or combination. Omron data can be read and written.

Convert

We have module solutions which allow integration directly into Notifier products as well as the stand alone solutions shown bottom right.

Range of Conversion Solutions

Depending on project requirements select from units with varying resources. and multi port devices. OEM and embedded solutions too.

FS20 Series 1x RS232/485 1x Ethernet 1x Lonworks
FS25 Series 2x RS232/485 1x Ethernet
FS30 Series 2x RS232 and 2x RS485 2x Ethernet 1x Lonworks FieldBus Support:eg Profibus, DeviceNet etcHot Standby Support
FS40 Series 10x RS232 and 2x RS485 2x Ethernet 1x Lonworks FieldBus Support: eg DH+, MB+, Profibus, DeviceNet etcHot Standby Support
SlotServer 1x RS232/485 1x Ethernet 1x Lonworks For Rockwell ControlLogix 5600

Lonworks and Fieldbus are options not proviced on base models.

Block Diagram

FS30 series shown for purposes of illustration. Capability depends on hardware, firmware and configuration.

NotifierSolutionImage2.gif

Chipkin Automation and Rapid Engineering

1. Many of the Notifier drivers for FieldServer were developed by Chipkin Automation Systems. We are experts to source code level.

2. Experience working with Notifier Systems. We have sold and installed many systems connecting Notifier panels to foreign building management systems and devices.

3.  We are system integration specialists.  We have worked with most of the Building Automation Systems before.

4.  We provide a free CAS BACnet explorer when you integrate to a system using BACnet.  This software tool, developed by us, helps your technicians prove and test the interface. This option will save you $600 and give you confidence should the dreaded 'integration finger pointing' occur.

Data Sheets and Manuals

PDF gif Image  –  Data Sheet – FieldServer Driver – Serial – FS-8700-09 – Notifier 1010/2020

PDF gif Image  –  Manual – FieldServer Driver – Serial – FS-8700-09 – Notifier 1010/2020

PDF gif Image  –  Data Sheet – FieldServer Driver – Serial – FS-8700-25 – Notifier INA

PDF gif Image  –  Manual – FieldServer Driver – Serial – FS-8700-25 – Notifier INA

PDF gif Image  –  Data Sheet – FieldServer Driver – Serial – FS-8700-90 – Notifier ONYX NFS-640

PDF gif Image  –  Manual – FieldServer Driver – Serial – FS-8700-90 – Notifier NFS-640 NFS-320 NFS2-640

PDF gif Image  –  Data Sheet – FieldServer Driver – Serial – FS-8700-95 – Notifier NFS3030

PDF gif Image  –  Manual – FieldServer Driver – Serial – FS-8700-95 – Notifier NFS3030

PDF gif Image  –  FieldServer Driver – Serial – FS-8700-130 – Notifier NCA2/NFS2-3030

PDF gif Image  –  Manual – FieldServer Driver – Serial – FS-8700-98 – Notifier NCA  (Driver Version 3)

PDF gif Image  –  Manual – FieldServer Driver – Serial – FS-8700-98 – Notifier NCA  (Driver Version 1)

PDF gif Image  –  Data Sheet – FieldServer Driver – Serial – FS-8700-26 – Notifier 200/300/400

PDF gif Image  –  Manual – FieldServer Driver – Serial – FS-8700-26 – Notifier AFP 200/300/400

PDF gif Image  –  Data Sheet – FieldServer Driver – Serial – FS-8700-52 – Notifier AM6000

PDF gif Image  –  Manual – FieldServer Driver – Serial – FS-8700-52 – Notifier AM6000

More Data Sheets…

Need Help

Notifier  Web Site:  www.notifier.com

Need more info ?  Call or email us.

Metasys® as used in this document is a trademark of Johnson Controls, Inc.

Contact Us

Contact us via phone (+1 866-383-1657) or leave a detailed message below for sales, support, or any other needs

*Required Field
*Required Field
I'd like to receive the newsletter. *Check email for confirmation.
*Required Field
8:00am - 12:00pm 12:00pm - 5:00pm
Message Sent Successfully