Hunter Industries ACC2 and ICC2 to KNX Gateway

The Hunter Industries ACC2 and ICC2 to KNX Gateway acts as a protocol converter.
The Classic QuickServer is a high performance, fully configurable, cost effective Building and Industrial Automation gateway for integrators to easily interface devices to networks in commercial buildings and industrial plants.
The Hunter Industries ACC2 gateway can be used to connect enabled Hunter Industries controllers such as the ACC2 Irrigation Controller. A single gateway can connect to multiple controllers using this driver.
The KNX driver allows the FieldServer to transfer data to and from devices using KNX protocol.
SKU:
CAS-QS-1x40-3211

Classic QuickServer Gateway (KNX)

Sierra Monitor is a leader in protocol gateways for the building automation industry, enabling system integrators and developers to prepare building automation and process control infrastructures for the future by breaking down protocol barriers.

With the QuickServer KNX Gateway, FieldServer enables data access from KNX networks to devices and networks utilizing open and proprietary protocols such as BACnet, Modbus, LonWorks, Metasys N2 by JCI, SNMP and more. With over 100 protocols available in the extensive FieldServer Driver Library, no other product can connect KNX to more products!

FieldServer is in thousands of installations with over 700 translation paths. These gateways are LonMark certified, BACnet compliant, Metasys N2 compatible and mission-critical tested.

QuickServer is a galvanic-isolated translator device on KNX/TP installations with control and monitoring capabilities. All EIS data types are supported, allowing communication to any kind of KNX devices in the installation, such as temperature sensors, shutters, light switches, actuators, alarms etc.

Each QuickServer includes browser-based tools to make it easy to set-up QuickServer and perform diagnostics including determination of status, network settings, node information, map descriptors and more. The USB flash drive also includes the Discovery utility to determine what FieldServers are on a network.

Hunter Industries ACC2

The Hunter ACC2 gateway can be used to connect to suitably enabled Hunter Industries controllers such as the ACC2 Irrigation Controller. The Driver can read and write data, change settings and issue commands to the irrigation system. A single gateway can connect to multiple controller’s using this driver.


The Gateway will be an active client in communications with the Hunter controller. This means that the gateway will issue messages to read/write data. The Hunter Controller ACC2 will be a passive server, waiting silently for messages from the gateway to which it will respond. The data read will be cached for serving via a 2nd protocol such as DNP3 to Cimplicity or Modbus / BACnet for a building management system. Any of the over 140 protocols in the gateway library may be connected to the Hunter Driver.

KNX

The KNX driver allows the FieldServer to transfer data to and from devices using KNX protocol. The Fieldbus connection is included with the FieldServer. The FieldServer can emulate a Passive Client.

The KNX driver enables data access from KNX networks to other FieldServer protocols. Most KNX data point types are supported, allowing communication to almost any kind of KNX device in the installation, such as temperature sensors, shutters, light switches, actuators, alarms etc. This allows BMS systems to access a KNX network using direct read and write of KNX configured groups. This setup does not require the use of ETS4 to configure the QuickServer KNX gateway.

The KNX protocol is a connectionless protocol and therefore supports multiple clients and multiple servers.

The QuickServer is intended to act as a Passive Client on the KNX bus and make information available to other protocols. 

I'd like to inquire about the Hunter Industries ACC2 and ICC2 to KNX Gateway CAS-QS-1x40-3211. Please provide me with a quote for this product.

Specifications

Classic QuickServer Specs: FS-QS-1X4X

Depending on what hardware you require, the specifications will contain different options..

Field Connections QuickServer
QuickServer Model Diagram
Environment
  • Operating Temperature: -40 to 75°C (-40 to 167°F)
  • Relative Humidity: 5-90% RH non-condensing
Power Requirements

9-30V DC or 12-24V AC
(RS-422 = 15-30V DC or 12-24V AC)
(M-Bus = 12-24V DC)
Current draw: @ 12V

  • FS-QS-1010, FS-QS-1210, FS-QS-1220: 240 mA

Physical Dimensions

  • Dimensions (WxDxH): 4.5x2.9x1.6 in. (11.5x7.4x4.1cm
  • Weight: 0.4 lbs (0.2 Kg)
  • Input voltage: 24 V DC nominal: 10-30V DC
Other

Configuration/Diagnostic utilities

  • Capacity: 250 points (FS-QS-104X), 500 points (FS-QS-124X), 3000 Points (FS-QS-134X), 5000 Points (FS-QS-144X)
  • Table, Wall or DIN rail mount
Communication
  • Baud: 4800, 9600, 19200, 38400, 57600, 115200
  • Start Bit: 7, 8
  • Stop Bit: 1, 2
  • Parity: Even, Odd, None
LonMark Certification on the QuickServer FS-QS-1XX1-XXX
  • SPID: 80:00:95:46:00:84:04:01
  • Profiles: 0000 - Node object (1), 0001 - Open Loop Sensor Object (5), 0003 - Open Loop Actuator Object (5)
  • Ethernet: 1, 2
  • Parity: 10/100 BaseT
Approvals
  • TUV Approved: to UL 916, EN 60950-1, EN 50491-3 and CSA C22.2 standards
  • BTL Mark:
  • LonMark Certified: (FS-QS-1011 and FS-QS-12X1)
  • RoHS Compliant
  • GOST-R Certified
  • CE and FCC
Jump List for File Explorer
Dimensions
FS-B3510 certifications

Block Diagrams

FS-8705-41 - Hunter Industries ACC2  Gateway - Block Diagramimports/blockDiagrams/LP KNX.jpg