Articles Directory: Explore Our Publications Page 51

Networked Robotics NTMS4 - How to Connect your NTMS4 in a Network Closet

Introduction This document describes how to connect an NTMS4 in a network closet. Using this method you will plug in probes or direct connections to other types of monitored devices into your compan…
Read More

SIA DC-03 - Official Standard Name

SIA DC-03-1990.01 (R2003.10) - DCS SIA Format Standard                This standard describes a standard format for communication between alarm system communicators and central station receivers. It d…
Read More

SIA DC-03 - Protocol Driver Capability Overview

DescriptionThe driver provides an interface to alarm panels that support the Security Industry Association (SIA) codes and which produce event messages formatted as described in this document. The DS…
Read More

Modbus Daniels - What is Enron or Daniels Modbus?

Did you know that we also do Modbus Integration Solutions? Chipkin has Modbus solutions for almost every situation. We are experts…
Read More

Modbus Daniels - How is data stored in Enron Modbus?

How is data stored in Enron Modbus?In Enron Modbus, there is a different table for each of the different data types.Information is stored in the Slave device in four different tables.One tables stores…
Read More

What physical layer does Metasys N2 by JCI use?

Metasys N2 by JCI is a master/slave control network that uses RS-485 as the physical layer. RS-485 is a standard for serial data transmission over shielded twisted pair cables. It supports half-duplex…
Read More

Decoding Metasys N2 Messages: Cable Tips for JCI

This section describes briefly what you need to know when designing an N2 Bus installation. A properly installed N2 Bus consists of an electrically continuous line of cable (…
Read More

Metasys N2 by JCI - How do I terminate a line

In order to properly terminate the N2 Bus, you need to know the two types of terminating devices. They are: • Switch-Terminating--device has an EOL switch or jumper; includes the NCM, DCM, XBN, XRE,…
Read More

Metasys N2 by JCI - Combine multiple N2 buses into a single virtual N2 bus

The S4 Open: N2 switch combines multiple N2 buses into a single virtual N2 bus, allowing supervisory controllers to manage much larger systems.  This is a highly cost effective alternative to using m…
Read More

Lonworks - What is Lontalk

Jargon WatchLonworks – a wide ranging term generally applied to describe the whole technology developed by Echelon. It is used frequently and ambiguously.LonTalk – A registred trademark belonging to E…
Read More

Lonworks - Do I need Lonmaker to integrate a gateway

LonWorks Data Conversion CAS can configure Lonworks gateways so that they can communicate with Lonworks devices without having to be commissioned and bound. For example, when we configure a Lonworks…
Read More

Simplex 4100 Networked Panel Addressing with a FieldServer

To monitor this point passively: Use the following Map Descriptor.  The length has been set to a large number to allow all the networked points to be collected. Other than that…
Read More

Contact Us

Contact us via phone (+1 866-383-1657) or leave a detailed message below for sales, support, or any other needs

*Required Field
*Required Field
I'd like to receive the newsletter. *Check email for confirmation.
*Required Field
8:00am - 12:00pm 12:00pm - 5:00pm
Message Sent Successfully