BGE Smart Energy Meter Integration - BACnet, SNMP, Ethernet/IP and More
Intro to BGE Smart Energy Meters
With a history of more than 200 years of service as the first gas utility in the U.S., BGE has a long-standing commitment to our customers and the community. It began in 1816 when Rembrandt Peale lit the first gas lamp in Baltimore, and it continues two centuries later with BGE and our customers still leading the way in energy innovation.
As a systems integrator, Chipkin has the capabilities to integrate many BGE Smart Energy Meters. Chipkin has successfully integrated and tested many of these devices and continues to add new ones.

For more information on BGE, click here!
BGE Smart Energy Meter Protocol
BGE Smart Energy Meters communicate using the Modbus RTU Serial communication Protocol. Chipkin offers multiple solutions that will allow you to integrate these devices to your BACnet Networks.
Not integrating to BACnet? No problem, we offer over 120 other protocols to integrate with. Too many to list here.
Contact Us to discuss your project needs, I am sure we can make the integration process an easy experience. Not only that, but all our solutions come with Free Modbus and BACnet Software for Testing.
Dual-Ethernet Port QuickServers
The Dual Ethernet Port QuickServer is the premium secure QuickServer for those needing the best and most secure networks. Besides being capable of handling everything that the classic QuickServer and the QuickServer can handle, it also contains 2 Ethernet ports, can convert up to 10,000 points and has a lot of new security features. It supports 1 RS-485/RS232 Port, 1 RS485 Port, and two Ethernet ports.
With two Ethernet ports, the dual-port QuickServer allows data to move seamlessly across disparate subnets allowing seamless integration with maximum security. Click here to read more about QuickServer Gateways
Classic QuickServers
The Classic QuickServer (FS-QS-1XXX) and Upgraded QuickServer (FS-QS-2XXX) are a family of high-performance, fully configurable, and cost-effective building and industrial automation protocol gateways. They are designed for integrators to easily interface devices to networks in commercial buildings, campuses, and industrial facilities.
There are six standard models that come in basic (250 points) or enhanced (500-5000 points) and can connect to serial (RS485 and RS232), Ethernet, and/or LonWorks as well as KNX and M-Bus
Chipkin provides RockWell devices for a wide number of conversions. Contact Us for a free consultation.
Multiport Gateway for BGE Smart Energy Meters
The FS-B3510 is one of the FS-X30 Series FieldServers designed to meet the needs of any system integrator.
The FS-B30 Series brings together the powerful FieldServer driver library with state-of-the-art gateway design. It supports 1,000 points which can be upgraded to 10,000 points allowing it to easily handle just about anything with no slowdown in performance.
Chipkin provides BGE Smart Energy Meter gateways for a wide number of conversions. Contact Us for a free consultation.
BGE Meters Integrated
Chipkin has configured and tested gateways for a wide range of BGE Products. See below for a list:
- Single-Phase Multifunction DIN rail Meter - SDM120
- Single-Phase Two Module DIN rail Meters - SDM220
- Meter - SDM230
- Smart Energy Meter - SDM630
- Smart Energy Analyzer - SMART X96-5
- Power Quality Meter - DRT710M
BGE Smart Energy Meters
Smart meters are digital, electric meters that wirelessly provide secure, two-way communication between the meter and BGE and also allow you access to more information about your usage. Similar meters exist for natural gas.
A Smart Meter provides three key benefits: More control over your energy use to help you save money, Better service by automatically sending meter readings (helping eliminate estimated bills and the need for a meter reader to visit your home), and Quicker response times during outages and more efficient outage restoration.
BACnet for Field Technicians (Free!)
Learning about BACnet? Want to update your BACnet knowledge? This free EBook will guide you through basic and advanced BACnet topics.
You can purchase a hardcopy of this book from Amazon or you can download the BACnet for Field Technicians for free from our website.
FREE CAS BACNET EXPLORER WITH THE PURCHASE OF A BACNET GATEWAY!
Purchase a FieldServer or CAS Gateway from us that contains any BACnet protocol and we will help you test and document the BACnet interface by providing a free full license to the CAS BACnet Explorer and a hardcopy of the BACnet booklet.
The USB key and booklet ships with the product.
Thanks for choosing Chipkin's protocol gateways, data clients, and integration services to meet your building and industrial automation requirements!
Chipkinâ"¢ is a building and industrial automation protocol expert. We develop, configure, install and support gateways (protocol converters), data loggers and remote monitor and controlling applications. Founded in October 2000, Chipkin provides expert solutions for converting BACnet®, Modbus®, and LonWorks®—to name just a few—and enabling interfaces for HVAC, fire, siren, intercom, lighting, transportation and fuel systems. The high-quality products we offer (including those from other vendors) interface with Simplexâ"¢, Notifierâ"¢, McQuayâ"¢, GEâ"¢ and many others—so you can rest assured that we will select the most appropriate solution for your application.
With Chipkin you are buying a solution. Our configuration expertise in this field combined with free BACnet and other tools ensure your success; and our customer support via phone, e-mail, and remote desktop tools means that we're there when you need us. Chipkin is a small responsive company, and we live or die by the quality of our service—and with offices in two-time zones—we can provide support when you need it. Give us a call now!
Customer Support
Chipkin is proud to provide support for the products we sell. For technical support, sales, and customer service, please contact us at 1 (866) 383-1657