BACnet Router Wi-Fi for Wireless Communication

The wireless BACnet Router connects BACnet/IP, BACnet Ethernet and BACnet MS/TP networks, with Wi-Fi connectivity and an IoT cloud interface.
The wireless BACnet Router offers a complete BACnet internetworking solution for BACnet/IP (LAN or Wi-Fi), BACnet Ethernet, and BACnet MS/TP networks as well as an immediate IoT cloud interface.
The BACnet Master-Slave/Token-Passing (MSTP) driver enables the FieldServer to facilitate data exchange with devices over Serial using the BACnet MSTP protocol.
The BACnet/IP driver enables the FieldServer to facilitate data exchange with devices over Ethernet using the BACnet/IP protocol.
The BACnet Ethernet driver allows the FieldServer to transfer data to and from devices over Ethernet using BACnet Ethernet protocol.
SKU:
FS-Router-BACW
SKU:
FS-Router-BACW
Price:
US$654

BACnet MSTP

The BACnet Master-Slave/Token-Passing (MS/TP) driver implements a data link protocol that uses the services of the RS-485 physical layer. See the FieldServer BACnet PIC statement for the level of conformance that this driver implements.

All information in a BACnet system is represented in terms of objects. The Object_Identifier is a 32-bit code that identifies the type of Object (also identified by the Object_Type Property) and its "Instance" number, which together uniquely identify the Object within its BACnet device. Theoretically, a BACnet device could have over four million Objects of a particular type. The Object_Name is a text string, which has a unique capability. BACnet devices may broadcast queries for devices that contain Objects with a specific Object_Name. This can greatly simplify project setup.

BACnet requires one Device Object to be present in every BACnet device. The Device Object makes information about the device and its capabilities available to other devices on the networks. Before one BACnet device starts control-related communications with another, it needs to obtain some of the information presented by the other device's Device Object. Unlike other Objects, the Device Object's Instance number must be unique across the entire BACnet internetwork because it is used to uniquely identify the BACnet devices. It may be used to conveniently identify the BACnet device from other devices during installation.

Standard object types are used to hold real time data and other information. Each Object Type is referenced by a number, for example 0 represents an Analog Input.

Each Object consists of a number of prescribed properties, the main property being the Present_Value. Objects are monitored and controlled through their properties. The Analog Input Object is representative of the Objects involved directly with control elements and many of its Properties reflect this.

BACnet IP

The BACnet/IP driver allows the FieldServer to transfer data to and from devices over Ethernet using BACnet/IP protocol. The FieldServer can emulate either a Server or Client.

All information in a BACnet system is represented in terms of objects. The Object_Identifier is a 32-bit code that identifies the type of Object (also identified by the Object_Type Property) and its "Instance" number, which together uniquely identify the Object within its BACnet device. Theoretically, a BACnet device could have over four million Objects of a particular type. The Object_Name is a text string, which has a unique capability.

BACnet devices may broadcast queries for devices that contain Objects with a specific Object_Name. This can greatly simplify project setup.

Every BACnet device must have a Device Object, which provides details about the device and its functionalities to other networked devices. Before engaging in control communications, a BACnet device must acquire pertinent information from the Device Object of the target device. Unlike other Objects, the Instance number of the Device Object must be unique across the entire BACnet internetwork, serving as the device's distinct identifier. This uniqueness facilitates easy identification of the BACnet device during installation and operation.

Standard object types are used to hold real time data and other information. Each Object Type is referenced by a number, for example 0 represents an Analog Input. See Appendix D.1 for abbreviation list.

Each Object consists of a number of prescribed properties, the main property being the Present_Value. Objects are monitored and controlled through their properties.

BACnet Router Wi-Fi

The wireless BACnet Router offers a complete BACnet internetworking solution for BACnet/IP (LAN or Wi-Fi), BACnet Ethernet, and BACnet MS/TP networks as well as an immediate IoT cloud interface.

The FS-ROUTER-BACW offers two RS-485 ports and is a cost-effective option for configurations of 64 or fewer BACnet MS/TP devices without the need for additional line drivers.

The BACnet Router has an easy one page configuration, greatly simplifying the installation process. The BACnet Explorer discovery feature allows the integrator to easily find all the BACnet devices connected to the router, greatly simplifying the commissioning process.

The BACnet Router has the unique ability to act as a Wi-Fi access point. Users can directly connect their mobile device to a BACnet Router without having to be on the facility's LAN or WAN to access the local applications.

Multiple BACnet Routing Connections

  • BACnet IP and BACnet MSTP
  • BACnet IP and BACnet IP
  • BACnet IP and BACnet Ethernet
  • BACnet MSTP and BACnet MSTP
  • BACnet MSTP and BACnet Ethernet

Ease of Use

  • BACnet Explorer functionality discovers devices connected to the FieldServer BACnet Router for diagnostics and troubleshooting.
  • BACnet Broadcast Management Device (BBMD) for a connection between different subnets, up to 50 devices supported on the Broadcast Distribution Table (BDT).
  • Configure easily on the web using a PC or mobile devices without additional software installations.
  • NAT support with secondary BACnet/IP connection for routing between public and private IP networks.
  • Foreign Device Registration (FDR), exposing up to 147 devices details on different subnets.
  • Wi-Fi access point allows for direct connection from any mobile device without having to be on the facility's LAN or WAN to access the router.
  • Onboard diagnostics allow easy troubleshooting for both serial and Ethernet communications.

Ease of Installation

  • MDIX to use any Ethernet cable for commissioning and installation.
  • DHCP to automatically obtain the IP setting from the network.
  • Software “ToolBox” to find and diagnose all FieldServer BACnet routers on the network.
  • A wide range of input power requirements, AC or DC.

BACnet Ethernet

The BACnet®1suite of drivers is designed to workwith the FieldServer products. One or more driversusing different Data Link Layer options could beconfigured to act as a gateway between BACnetsystems and RTU, SCADA's and PLC’s using a widevariety of protocols.

This is relevant to the following FieldServerDrivers:

  • FS-8700-16 BACnet/PTP
  • FS-8700-73 BACnet/MSTP
  • FS-8700-07 BACnet/ARCnet
  • FS-8704-06 BACnet/IP
  • FS-8704-02 BACnet/Ethernet
BACnet Vendor Name: Sierra Monitor CorporationBACnet Vendor ID: 37  

I'd like to inquire about the BACnet Router Wi-Fi for Wireless Communication FS-Router-BACW. Please provide me with a quote for this product.

Block Diagrams

Wifi BACnet Router Block diagramBACnet Combined Block Diagram

Additional Information

BACnet MSTP to IP

A BACnet Router is used to connect MSTP trunks to BACNetIP systems. The router itself is a device on the IP and on the MSTP side. The router can also act as BBMD device allowing messages to cross from one subnet to another.

BACnet BBMD

BACnet messages cannot cross from one subnet to another except under special circumstances.

Most BACnet sequenc es of messages begin with a broadcast called 'who is'. All devices respond with 'I am'. That is how they are discovered. It is also how many system confirm the device is still there.

Broadcasts can't cross routers (they are blocked) and therefore devices on the other side of a router cannot e discovered.


BBMD is the name of the BACNet technology that resolves these issues. The BACNet ROuter sold by CAS provides BBMD services as do all FieldServer BACNet products when configured as clients.

Logos

imports/logos/Logo BTL Bacnet Test Lab
Logo bacnet1

Contact Us

Contact us via phone (+1 866-383-1657) or leave a detailed message below for sales, support, or any other needs

*Required Field
*Required Field
I'd like to receive the newsletter. *Check email for confirmation.
*Required Field
8:00am - 12:00pm 12:00pm - 5:00pm
Message Sent Successfully